![Vertiv Avocent Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/vertiv/avocent/avocent_installer-user-manual_1008004106.webp)
Appendix F: Troubleshooting SPs
If you cannot discover or manually add an SP, try the following:
•
Verify the SP is enabled in the BIOS of the server.
•
Some SP settings are stored in the main BIOS <
F2
> or <
DEL
>.
•
Some SP settings are in an alternate BIOS <
ctrl+D
><
ctrl+E
><
F8
>.
•
Some SP settings are in both the main and alternate BIOS.
•
Ensure the SP is using the dedicated interface if the SP is physically connected to the appliance or the network.
•
Ensure the SP is sharing or using side-band with NIC1 if the SP will be logically managed.
•
Ensure the username and password are correctly configured.
•
Access the SP BIOS and reset the password to ensure accuracy of the credentials.
•
Ensure the SP has an appropriate IP address assigned.
•
Ensure the appliance and the SP are on, or are accessible to, the same network.
•
The network must match the IP address of the SP and the network must be able to route the SP to the network
the appliance is connected to. This can often be tested by using a ping from the appliance command shell.
•
If you cannot ping the SP, the SP may only allow communication via IPMI. If the username/password and
network routing are all correct, the appliance will be able to communicate with IPMI only SPs.
•
DHCP works in request-respond fashion. The SP must request a DHCP address before the appliance can
provide one. Many SPs will retain their assigned DHCP IP address despite having been turned off or if the
cable has been disconnected and re-connected. The best way to resolve this is to force the SP to use a static IP
address (save/restart) then reset it to DHCP while connected to the appliance. This will cause the SP to request
an address from the appliance, and the appliance can now discover the SP.
•
If the SP is accessible and the username/password is correct, verify that IPMI (or Telnet/SSH as appropriate) is
enabled in the SP or is assigned to the appropriate NIC interface. Validate the required SP communication
protocol and firmware version in the appliance release notes.
Vertiv
| Avocent® Universal Management Gateway Appliance Installer/User Guide |
100