FCC ID: K6610444140
IC ID: 511B-10444140
Alignment
2/5
Vertex Standard Co., Ltd.
Required Test Equipment
RF signal generator: calibrated output level at
1000 MHz (0 dBµ =1.0 µV - closed circuit)
Deviation Meter (linear detector)
AF Millivoltmeter
SINAD Meter
Inline Wattmeter with 5% accuracy at 1000 MHz
Regulated DC Power Supply: adjustable from 10 to 17 VDC, 15A
50
Ω
Non-reactive Dummy Load: 100W at 1000 MHz
Frequency Counter: >0.1-ppm accuracy at 1000 MHz
AF Signal Generator
DC Voltmeter: high impedance
RF Sampling Coupler (attenuation pad)
AF Dummy Load: 4
Ω
, 20W
Oscilloscope
Spectrum Analyzer
IBM PC/compatible computer w/ VERTEX STANDARD VPL-1 programming cable and CE-49 channel
programming editor.
50-
Ω
RF Signal
Dummy load
Generator
Inline RF Sampling
Wattmater
Coupler Transmitter
Deviation Meter VPL-1
Frequeuncy IBM PC Power Supply
Counter COM Port 13.6V DC