Required Test Equipment

Required Test Equipment

Required Test Equipment

Required Test Equipment

R

 

Radio Tester with calibrated output level at 200 MHz

R

 

In-line Wattmeter with 5% accuracy at 200 MHz

R

 

50-

, 10-W RF Dummy Load

R

 

Regulated DC Power Supply adjustable from 3 to 15 VDC, 2A

R

 

Frequency Counter: ±0.2 ppm accuracy at 200 MHz

R

 

AF Signal Generator

R

 

AC Voltmeter

R

 

DC Voltmeter: high impedance

R

 

VHF Sampling Coupler

Alignment Preparation & Precautions

Alignment Preparation & Precautions

Alignment Preparation & Precautions

Alignment Preparation & Precautions
A 50-

 RF load and in-line wattmeter must be connected to the main antenna jack in

all procedures that call for transmission, except where specified otherwise. Correct
alignment is not possible with an antenna. After completing one step, read the next
step to see if the same test equipment is required. If not, remove the test equipment
(except dummy load and wattmeter, if connected) before proceeding.

Correct alignment requires that the ambient temperature be the same as that of the
transceiver and test equipment, and that this temperature be held constant between
20~30 °C (68-86 °F). When the transceiver is brought into the shop from hot or cold air,
it should be allowed some time to come to room temperature before alignment.
Whenever possible, alignments should be made with oscillator shields and circuit
boards firmly affixed in place. Also, the test equipment must be thoroughly warmed up
before beginning.

Set up the test equipment as shown below for transceiver alignment, apply 7.2 VDC
power to the transceiver. Refer to the drawings for Alignment Points.

PLL Reference Frequency

PLL Reference Frequency

PLL Reference Frequency

PLL Reference Frequency

R

 

Connect the wattmeter, dummy load and frequency counter connected to the
antenna jack, and tune the transceiver to 120.000 MHz.

R

 

Transmit, and adjust 

TC1001

 on the RF Unit, if necessary, so the counter

frequency is 120.000 MHz (±100 Hz).

Содержание VXA-150

Страница 1: ...ould any alignment be attempted unless the normal function and operation of the transceiver are clearly understood the cause of the malfunction has been clearly pinpointed and any faulty components replaced and realignment determined to be absolutely necessary Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Vertex Standard reserves the right to change...

Страница 2: ...is required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 30 C 68 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed some time to come to ro...

Страница 3: ...ernal System Alignment Routine Internal System Alignment Routine Internal System Alignment Routine This feature uses a programmed routine in the transceiver which replaces many previously complex discrete component settings and adjustments with digitally controlled settings via the CHANNEL selector knob Transceiver adjustments include Squelch Hysteresis Adjustment Squelch Threshold Adjustment Sque...

Страница 4: ...and hold the in the CHANNEL selector knob for 2 second to save all setting and exit Resetting the CPU Resetting the CPU Resetting the CPU Resetting the CPU If you are unable to gain control of the transceiver or if you want to clear all memories and settings to their factory defaults press and holding the MONITOR button and PTT switch while turning the transceiver on ...

Отзывы: