VX-450 Series UHF Band Service Manual
Alignment
Introduction
The
VX-450
series is carefully aligned at the factory
for the specified performance across the frequency
range specified for each version. Realignment should
therefore not be necessary except in the event of a
component failure, or altering version type. All com-
ponent replacement and service should be per-
formed only by an authorized
Vertex Standard
rep-
resentative, or the warranty policy may be void.
The following procedures cover the sometimes crit-
ical and tedious adjustments that are not normally
required once the transceiver has left the factory.
However, if damage occurs and some parts subse-
quently are replaced, realignment may be required.
If a sudden problem occurs during normal opera-
tion, it is likely due to component failure; realign-
ment should not be done until after the faulty com-
ponent has been replaced.
We recommend that servicing be performed only by
authorized
Vertex Standard
service technicians who
are experienced with the circuitry and fully equipped
for repair and alignment. Therefore, if a fault is sus-
pected, contact the dealer from whom the transceiv-
er was purchased for instructions regarding repair.
Authorized
Vertex Standard
service technicians re-
align all circuits and make complete performance
checks to ensure compliance with factory specifica-
tions after replacing any faulty components.
Those who do undertake any of the following align-
ments are cautioned to proceed at their own risk.
Problems caused by unauthorized attempts at re-
alignment are not covered by the warranty policy.
Also,
Vertex Standard
reserves the right to change
circuits and alignment procedures in the interest of
improved performance, without notifying owners.
Under no circumstances should any alignment be
attempted unless the normal function and operation
of the transceiver are clearly understood, the cause
of the malfunction has been clearly pinpointed and
any faulty components replaced, and realignment
determined to be absolutely necessary.
The following test equipment (and thorough famil-
iarity with its correct use) is necessary for complete
realignment. Correction of problems caused by mis-
alignment resulting from use of improper test equip-
ment is not covered under the warranty policy. While
most steps do not require all of the equipment list-
ed, the interactions of some adjustments may require
that more complex adjustments be performed after-
wards. Do not attempt to perform only a single step
unless it is clearly isolated electrically from all other
steps. Have all test equipment ready before begin-
ning, and follow all of the steps in a section in the
order presented.
Required Test Equipment
RF Signal Generator with calibrated output level
at 600 MHz
Oscilloscope
Deviation Meter (linear detector)
In-line Wattmeter with 5 % accuracy at 600 MHz
50 Ohm RF Dummy Load with power rating 10
W at 600 MHz
Regulated DC Power Supply (standard 7.5 V DC,
3 A)
Frequency Counter with 0.2 ppm accuracy at 600
MHz
Audio Signal Generator
AC Voltmeter
DC Voltmeter
UHF Sampling Coupler
IBM® PC/compatible Computer with Microsoft
®
Windows
®
2000, XP, Vista or Windows7
Vertex Standard CE115 PC Programming Soft-
ware
Vertex Standard FIF-12 USB Programming Inter-
face and CT-104A, CT-106, or CT-171 PC Program-
ming Cable.
Vertex Standard FRB-6 Tuning Interface Box and
CT-160 Connection Cable.
Vertex Standard CN-2A (P/N: A08420002) An-
tenna Connector
Содержание VX-450 series
Страница 8: ...8 VX 450 Series UHF Band Service Manual Block Diagram Version A D 16 key 4 key Type RF Section...
Страница 10: ...10 VX 450 Series UHF Band Service Manual Block Diagram Version A D 16 key 4 key Type AF Section...
Страница 11: ...11 VX 450 Series UHF Band Service Manual Block Diagram Version A D 16 key 4 key Type Controller Section...
Страница 12: ...12 VX 450 Series UHF Band Service Manual Block Diagram Version A D Non key Type RF Section...
Страница 14: ...14 VX 450 Series UHF Band Service Manual Block Diagram Version A D Non key Type AF Section...
Страница 15: ...15 VX 450 Series UHF Band Service Manual Block Diagram Version A D Non key Type Controller Section...
Страница 16: ...16 VX 450 Series UHF Band Service Manual Block Diagram Version I K 16 key 4 key Type RF Section...
Страница 18: ...18 VX 450 Series UHF Band Service Manual Block Diagram Version I K 16 key 4 key Type AF Section...
Страница 19: ...19 VX 450 Series UHF Band Service Manual Block Diagram Version I K 16 key 4 key Type Controller Section...
Страница 20: ...20 VX 450 Series UHF Band Service Manual Block Diagram Version I K Non key Type RF Section...
Страница 22: ...22 VX 450 Series UHF Band Service Manual Block Diagram Version I K Non key Type AF Section...
Страница 23: ...23 VX 450 Series UHF Band Service Manual Block Diagram Version I K Non key Type Controller Section...
Страница 44: ...44 VX 450 Series UHF Band Service Manual MAIN Unit Circuit Diagram Version A D 16 key 4 key Type Lot 1 4...
Страница 47: ...47 VX 450 Series UHF Band Service Manual MAIN Unit Circuit Diagram Version A D 16 key 4 key Type Lot 5 6...
Страница 50: ...50 VX 450 Series UHF Band Service Manual MAIN Unit Circuit Diagram Version A D 16 key 4 key Type Lot 7...
Страница 53: ...53 VX 450 Series UHF Band Service Manual MAIN Unit Circuit Diagram Version A D Non key Type Lot 1 7...
Страница 56: ...56 VX 450 Series UHF Band Service Manual MAIN Unit Circuit Diagram Version A D Non key Type Lot 8...
Страница 59: ...59 VX 450 Series UHF Band I Band Service Manual MAIN 2 Unit Circuit Diagram Version I K 16 key 4 key Type...
Страница 62: ...62 VX 450 Series UHF Band I Band Service Manual MAIN 2 Unit Circuit Diagram Version I K Non key Type...
Страница 65: ...65 VX 450 Series UHF Band Service Manual DISPLAY Unit Circuit Diagram 16 key 4 key Type Lot 1 4...
Страница 68: ...68 VX 450 Series UHF Band Service Manual DISPLAY Unit Circuit Diagram 16 key 4 key Type Lot 5 Circuit Diagram...