FCC ID: K66VX-2R

Alignment

Vertex Standard Co., Ltd.

4

PLL Reference Frequency 

(PLL REF)

 Transmit and adjust the counter frequency for within ±300Hz by rotating the
DIAL, then press the [

V/M]

 button. Rotate the DIAL to select the next setting.

   

430MHz band Alignment

  Squelch Hysteresis Adjust 

(HIS)

  Rotate the DIAL for minimum squelch hysteresis, then press the [V/M] button.
Rotate the DIAL to select the next setting.

  Squelch Preset Threshold 

(tHL)

  Inject a -15dBµ RF signal (1 kHz tone @ ±3.5kHz deviation), then press the [V/M]
button. Rotate the DIAL to select the next setting.

  Squelch Preset Tight 

(tIg)

  Adjust the generator level for a -4dBµ signal, then press the [V/M] button. Rotate
the DIAL to select the next setting.

  Low-Scale S-1 Adjustment 

(S1)

  Adjust the generator level to -7dBµ (1 kHz tone @ ±3.5kHz deviation), then press
the [V/M] button. Rotate the DIAL to select the next setting.

  S-Meter Full-Scale Adjust 

(S9)

  Adjust the generator level to +20dBµ (1 kHz tone @ ±3.5kHz deviation), then press
the [V/M] button. Rotate the DIAL to select the next setting.

  Wide Low-Scale S-1 Adjustment 

(S1)

  Adjust the generator level to 0dBµ (1 kHz tone @ ±20kHz deviation), then press
the [V/M] button. Rotate the DIAL to select the next setting.

  Wide S-Meter Full-Scale Adjust 

(S9)

  Adjust the generator level to +20dBµ (1 kHz tone @ ±20kHz deviation), then press
the [V/M] button. Rotate the DIAL to select the next setting.

  High TX Power Adjust 

(HPo)

  Transmit and adjust the output power level for 2W ±0.3W by rotating DIAL, then
press the [V/M] button. Rotate the DIAL to select the next setting.

  Low TX Power Adjust 

(LPo)

Transmit and adjust the output power level for 50 mW ±30 mW by rotating DIAL,
then press the [V/M] button. Rotate the DIAL to select the next setting.

  TX Deviation Adjustment 

(dEV)

 Transmit and adjust the deviation for 4.2KHz ±0.2KHz by rotating DIAL, then
press the [V/M] button. Rotate the DIAL to select the next setting.

This completes the UHF band internal alignment routine, to save all settings and

exit, press [BAND] button.

Содержание VX-2R

Страница 1: ...r Authorized Yaesu service technicians realign all circuits and make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Yaesu reserves the...

Страница 2: ... the main antenna jack in all procedures that call for transmission alignment is not possible with an antenna After completing one step read the next step to see if the same test equipment is required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test...

Страница 3: ...in The display will show the first setting Note that the first few settings are not adjustable and are left as set from the factory In the alignment process each adjustment is selected by rotating the DIAL Alignment is performed by Pressing the V M button Injecting a signal of the required frequency and level then Pressing the V M button after a level setting or adjustment is made This second pres...

Страница 4: ...ust S9 Adjust the generator level to 20dBµ 1 kHz tone 3 5kHz deviation then press the V M button Rotate the DIAL to select the next setting Wide Low Scale S 1 Adjustment S1 Adjust the generator level to 0dBµ 1 kHz tone 20kHz deviation then press the V M button Rotate the DIAL to select the next setting Wide S Meter Full Scale Adjust S9 Adjust the generator level to 20dBµ 1 kHz tone 20kHz deviation...

Страница 5: ... button Rotate the DIAL to select the next setting Wide Low Scale S 1 Adjustment S1 Adjust the generator level to 0dBµ 1 kHz tone 20kHz deviation then press the V M button Rotate the DIAL to select the next setting Wide S Meter Full Scale Adjust S9 Adjust the generator level to 20dBµ 1 kHz tone 20kHz deviation then press the V M button Rotate the DIAL to select the next setting High TX Power Adjus...

Отзывы: