Alignment

Vertex Standard Co., Ltd.

3

and circuit boards firmly affixed in place. Also, the test equipment must be thoroughly

warmed up before beginning.

Notes: Signal levels in dB referred to in alignment are based on 0 dBµ = 0.5 µV.

All items tune and/or adjust by Auto-Tuning Mode or Manual Tuning Mode.

PLL Reference Frequency

ˆ

  With the wattmeter, dummy load and frequency counter connected to the antenna jack.

ˆ

  Tune the transceiver 435.05 MHz and set the TX power level to low power mode.

ˆ

  Key the transceiver, adjust the counter frequency is within ±100 Hz of 435.05 MHz.

 

Transmitter Deviation

ˆ

  With the wattmeter, dummy load and deviation meter connected to the antenna jack.

ˆ

  Inject a 1 kHz audio signal as a level of 80 mV to the microphone-input port.

ˆ

  Key the transmitter on 440.05 MHz. Adjust the frequency deviation is within 4.3-4.7 kHz

on the deviation meter.

 

CTCSS Deviation

ˆ

  With the wattmeter, dummy load and deviation meter connected to the antenna jack.

ˆ

  Key the transmitter on 440.05 MHz. Adjust the frequency deviation is within 0.65-0.75

kHz on the deviation meter.

 

DCS Deviation

ˆ

  With the wattmeter, dummy load and deviation meter connected to the antenna jack.

ˆ

  Key the transmitter on 440.05 MHz. Adjust the frequency deviation is within 0.65-0.75

kHz on the deviation meter.

Содержание VX-127

Страница 1: ...t servicing be performed only by authorized Yaesu service technicians who are experienced with the circuitry and fully equipped for repair and alignment Therefore if a fault is suspected contact the dealer from whom the transceiver was purchased for instructions regarding repair Authorized Yaesu service technicians realign all circuits and make complete performance checks to ensure compliance with...

Страница 2: ...cilloscope Spectrum Analyzer Deviation Meter linear detector AF Milivoltmetr AF Dummy Load 8 Ω 1 W DC Voltmeter high impedance Inline Wattmeter with 5 accuracy at 500 MHz 50 Ohm non reactive Dummy Load 10 watts at 500 MHz VHF UHF Sampling Coupler Alignment Preparation Precautions A dummy load and inline wattmeter must be connected to the main antenna jack in all procedures that call for transmissi...

Страница 3: ...counter frequency is within 100 Hz of 435 05 MHz Transmitter Deviation With the wattmeter dummy load and deviation meter connected to the antenna jack Inject a 1 kHz audio signal as a level of 80 mV to the microphone input port Key the transmitter on 440 05 MHz Adjust the frequency deviation is within 4 3 4 7 kHz on the deviation meter CTCSS Deviation With the wattmeter dummy load and deviation me...

Страница 4: ...e power meter HI Key the transmitter on 440 05 MHz Adjust the output power is within 2 0 1 W on the power meter MID Key the transmitter on 440 05 MHz Adjust the output power is within 0 5 0 05 W on the power meter LOW Receiver Sensitivity With the dummy load and SINAD meter connected to the external speaker jack Inject a RF signal as a level of 9 dBµV to the antenna jack Tune the receiver on 440 0...

Отзывы: