background image

FCC ID: K6630483X3D 

IC: 511B-30483X3S 

Alignment 

5/5

 

Vertex Standard Co., Ltd. 

1kHz modulation). 

ˆ

  Set the output level to -8dBµ. 

ˆ

  Press the [

ITEM

] key till “

04:THRESH

” is displayed. 

ˆ

 Press 

[

GET

] key to obtain the squelch threshold level. 

ˆ

 Press 

[

SET

] key to fix the alignment data. 

 

Adjustment of the Squelch Tight 

ˆ

  Connect the RF signal generator to the antenna jack. 

ˆ

  Set the output frequency at 156.8000MHz with standard modulation (±3.0kHz deviation, 

1kHz modulation). 

ˆ

  Set the output level to +3dBµ. 

ˆ

  Press the [

ITEM

] key till “

05:TIGHT

” is displayed. 

ˆ

 Press 

[

GET

] key to obtain the squelch tight level. 

ˆ

 Press 

[

SET

] key to fix the alignment data. 

 

Adjustment of DSC Squelch threshold 

ˆ

  Connect the RF signal generator to the antenna jack. 

ˆ

  Set the output frequency at 156.5250MHz with standard modulation (±3.0kHz deviation, 

1kHz modulation). 

ˆ

  Set the output level to -4dBµ. 

ˆ

  Press the [

ITEM

] key till “

06:CH70 SQL

” is displayed. 

ˆ

 Press 

[

GET

] key to obtain the DSC squelch threshold level. 

ˆ

 Press 

[

SET

] key to fix the alignment data. 

 

Adjustment of DC VOLT 

ˆ

  Set the DC power supply to 13.8VDC. 

ˆ

  Press the [

ITEM

] key till “

07:DC VOLT

” is displayed. 

ˆ

 Press 

[

GET

] key to obtain the DC voltage. 

ˆ

 Press 

[

SET

] key to fix the alignment data. 

 

Adjustment of the LCD Contrast 

ˆ

  Press the [

ITEM

] key till “

08:CONTR.

” is displayed. 

ˆ

 Press 

[

] or [

] keys to set a good view of the LCD contrast. 

ˆ

 Press 

[

SET

] key to fix the alignment data. 

 

Closing the Alignment Mode 

Press and hold the [

DISTRESS

] key until sounds a beep to memorize all alignment data. 

Then press and hold the [

PWR

] key to turn the radio off.  

 

Содержание GX1600

Страница 1: ...e complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change circu...

Страница 2: ...orrect alignment is not possible with an antenna After completing one step read the following step to determine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be ...

Страница 3: ...nthetic tone of 1300 Hz and 2100 Hz 2nd transmission 1300 Hz 3rd transmission 2100 Hz 4th transmission No modulation 5th transmission Return to 1st transmission C Scan the channels between EXP03 and EXP04 in the SCAN mode D In the test mode a transmit time out timer function TOT becomes off E A user s MMSI is set to 123456789 for DSC tests temporarily Starting the Test Mode Press the PWR switch wh...

Страница 4: ...he PTT key to set the power to 0 8 0 1W Press SET key to fix the alignment data Adjustment of the Maximum Deviation Connect the linear detector to the antenna jack and connect the AF signal generator to the microphone jack Set the AF signal output level to 200mVrms at 1kHz Press the ITEM key till 02 Devi is displayed Press or keys while pressing the PTT key to set the deviation to 4 4 0 1kHz Press...

Страница 5: ...onnect the RF signal generator to the antenna jack Set the output frequency at 156 5250MHz with standard modulation 3 0kHz deviation 1kHz modulation Set the output level to 4dBµ Press the ITEM key till 06 CH70 SQL is displayed Press GET key to obtain the DSC squelch threshold level Press SET key to fix the alignment data Adjustment of DC VOLT Set the DC power supply to 13 8VDC Press the ITEM key t...

Отзывы: