background image

FCC ID: K6630303X3S 

IC ID: 511B-30303X3S 

Alignment 

1/6

 

Vertex Standard Co,. Ltd. 

GX1000S Alignment 

 

The 

GX1000S

 has been carefully aligned at the factory for the specified performance 

across the marine band. 

Realignment should therefore not be necessary except in the event of a component 

failure. All component replacement and service should be performed only by an authorized 

Standard Horizon representative, or the warranty policy may be voided.  

The following procedures cover the sometimes critical and tedious adjustments that are 

not normally required once the transceiver has left the factory. However, if damage occurs 

and some parts are replaced, realignment may be required. If a sudden problem occurs 

during normal operation, it is likely due to component failure; realignment should not be 

done until after the faulty component has been replaced. 

We recommend that servicing be performed only by authorized Standard Horizon 

service technicians who are experienced with the circuitry and fully equipped for repair and 

alignment. Therefore, if a fault is suspected, contact the dealer from whom the transceiver 

was purchased for instructions regarding repair. Authorized Standard Horizon service 

technicians realign all circuits and make complete performance checks to ensure 

compliance with factory specifications after replacing any faulty components.  

Those who do undertake any of the following alignments are cautioned to proceed at 

their own risk. Problems caused by unauthorized attempts at realignment are not covered 

by the warranty policy. Also, Standard Horizon, a division of VERTEX STANDARD, must 

reserve the right to change circuits and alignment procedures in the interest of improved 

performance, without notifying owners. Under no circumstances should any alignment be 

attempted unless the normal function and operation of the transceiver are clearly 

understood, the cause of the malfunction has been clearly pinpointed and any faulty 

components replaced, and the need for realignment determined to be absolutely necessary. 

The following test equipment (and thorough familiarity with its correct use) is necessary 

for complete realignment. Correction of problems caused by misalignment resulting from 

use of improper test equipment is not covered under the warranty policy. While most steps 

do not require all of the equipment listed, the interactions of some adjustments may require 

that more complex adjustments be performed afterwards. Do not attempt to perform only a 

single step unless it is clearly isolated electrically from all other steps. Have all test 

equipment ready before beginning, and follow all of the steps in a section in the order 

presented. 

 

Содержание GX1000S

Страница 1: ...make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change ci...

Страница 2: ...etermine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from ho...

Страница 3: ...idth Adjustment Connect the wattmeter and 50 ohm dummy load to the antenna jack Use the H L key to set transceiver to high power and set the channel to CH16 With the PTT switch pressed adjust VR1001 so that RF power is 25 W Use the H L key to set transceiver to low power and set the channel to CH16 With the PTT switch pressed adjust VR1002 so that RF power is 0 8 W Adjustment of PLL Frequency Adju...

Страница 4: ...ave form shown in below is obtained Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form varies with measuring instruments It is impotent to take the lowest possible value at the stop band near 150 MHz and the highest possible value at the band near 156 MHz Each coil shall be adjusted at the range...

Страница 5: ... Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the test equipment as shown below Press and hold the H L key confirm that the position data is displayed on the...

Страница 6: ...I is displayed in the LCD of the test transceiver Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the confirmation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the confirmation transceiver ...