FT-950
Operating Manual
Vertex Standard Co., Ltd.
127
Function: Programs a band to be skipped while selecting bands using the [CLAR/
VFO-B] knob.
To program the band to be skipped, rotate the [CLAR/VFO-B] knob to recall the band
to be skipped while selecting bands via the [CLAR/VFO-B] knob, then press the [ENT]
button to change this setting to “ON” (a “d” notation will replace the “E” notation).
Repeat the same procedure to cancel the setting (skipped “Off”: “d” notation appears).
TX AUDIO Group
091 TAUD EQ1 FRQ
Function: Selects the center frequency of the lower range for the parametric
microphone equalizer.
Available Values: OFF/100 ~ 700 Hz (100 Hz/step)
Default Setting: OFF
OFF:
The equalizer gain and Q-factor are set to factory defaults (flat).
100 ~ 700: Center frequencies of 100 Hz ~ 700 Hz.
You may adjust the equalizer gain and Q-factor at this selected audio frequency via
menu items “092 TAUD EQ1 LVL” and “093 TAUD EQ1 BW.”
092 TAUD EQ1 LVL
Function: Adjusts the equalizer gain of the low range of the parametric microphone
equalizer.
Available Values: –10 ~ +10
Default Setting: +5
093 TAUD EQ1 BW
Function: Adjusts the Q-factor of the low range of the parametric microphone equalizer.
Available Values: 1 ~ 10
Default Setting: 10
094 TAUD EQ2 FRQ
Function: Selects the center frequency of the middle range for the parametric
microphone equalizer.
Available Values: OFF/700 ~ 1500 Hz (100 Hz/step)
Default Setting: OFF
OFF:
The equalizer gain and Q-factor are set to factory defaults (flat).
700 ~ 1500: Center frequencies of 700 Hz ~ 1500 Hz.