background image

After creating CF1 and CF2 cards, follow the instructions below 

 

*We recommend you save to the CF card, any personal settings you want to restore after the update. Please 
see the DMU-2000 Data Management Operation Manual for the procedure to save your settings to a CF 
card. Map and Time settings will be set to default. 
 

*When you insert the CF card into the slot, please insure that the white side (ridge side) of the CF card 
is up. If the CF card is inserted incorrectly, the DMU-2000

 

may be damaged.

 

 

 

1.

 

Turn off the DMU power switch on the rear panel and wait 1 minute. 

2.

 

Connect a keyboard, if one is not already connected. 

3.

 

Insert the system Compact Flash Card 

CF1

 (V0.xx-sys)

 

into the DMU card slot.

 

 

4.

 

Turn the DMU rear panel power switch on. 

5.

 

When the question appears, “CF has system update file, Are you sure to update? (y/n)>”  
Please answer 

yes

 (y + enter). 

6.

 

Wait a minute for the system to check the current version. The program level will be shown on the 
monitor display. Answer yes or no (y + enter, or n + enter) from the keyboard to each question of 
the install sequence. If the present version and the new version listed on the screen are identical 
numbers, you should answer 

no

. (If you answer no, when the screen blanks, remove the 

CF1

 card, 

or the system will repeat the sequence.) If the new version is higher, answer 

yes 

(y + enter).   

7.

 

When programming is complete, the screen will be blank. Remove the 

CF1

 card and Turn the 

rear panel DMU power switch off. Wait one minute. 

 

Now you can insert CF2 (app) and Follow the same procedure instructions 1 thru 7: 

 
8.

 

When programming is complete, remove the Compact flash card 

CF2 

(V0.xx-app). Turn the rear 

panel DMU power switch off. Wait one minute. 

9.

 

Turn on the FT-2000/D, FT-950 or FTdx5000 and the DMU-2000 rear and front power switches, 
and confirm the DMU firmware is updated to V4.21 or V5.11 depending on the type of DMU-
2000 computer. Refer to the top of page 1 to check which version DMU software you have on 
your unit. 

10.

 

You will need to re-enter your map location, clock and other settings if necessary. The updating 
process is now complete. 

                               

We hope this new software will increase your enjoyment of your DMU-2000. Thank you for choosing 
Yaesu radios. If you have any problems or questions please contact Vertex Standard, Amateur Tech 
Support. 

[email protected]

 

 
Best regards, 

 

Mikio Maruya, WA6F 

Executive Vice President  
Engineering & Customer Service 
 
Vertex Standard USA, Inc. 

 

Vertex Standard USA, Inc. | 10900 Walker St. | Cypress, CA  90630 | 714.827-7600 | FAX: 714.827-8100  

www.vertexstandard.com 