CAUTION: Only down load the correct software for your version 0.08/4.21 or 0.09/5.11 for the DMU-
2000. Do not keep both versions on your computer.  

 

Ver. 4.21 or 5.11 CPU implements improvements also includes all previous updates): 

 

ONLY Changes to support the New FTdx5000 Series Transceiver 

 
 

Install the data file to PC 

 

1.

 

Down load the DMU-2000 data file [

DMU-2000_V008_2-25-10.zip

] or [

DMU-2000_V009_2-

25-10.zip

] from the following website: 

 

http://www.yaesu.com/indexVS.cfm?cmd=DisplayProducts&ProdCatID=102&encProdID=66EA
91711DFB68C03DED4AD35153E12C&DivisionID=65&isArchived=0

 

 
2.

 

Save the DMU-2000 data file [

DMU-2000_2-25-10.zip

] to the desktop on your computer. 

3.

 

Unzip and Extract the contents of [

DMU-2000_2-25-10.zip

] to the desktop of your computer. 

4.

 

You will find the 

CF1

 and 

CF2

 folders on your desktop.  

 
The programmer and software are now stored on your computer on the desktop. The files designated 
in the last step above are ready to create two CF cards to use in updating your DMU-2000.  
 

*You must have two separate, blank CF cards (32 MB or more) and have a CF card reader slot.  
 
NOTE

: Do not copy the folders to the CF cards, only the files (V0.xxx WinZip and md5sum). The 

system and the application files must be on separate CF cards. Do not save them to the same CF card.  
Be sure the CF card does not contain any previous data or partitions. You may need to make a single 
patrician and reformat a previously used CF card.  

 

Now you will transfer each of the needed files to separate CF cards. When you open the CF1 folder 
you will see the two files. Copy both system files and paste them to the CF card drive and create a CF 
card. Remove the CF1 card and insert another card. Now open the CF2 folder and copy or paste both 
application files to the CF card drive and create a CF card.   
It is strongly recommended that you mark each CF card as CF1 and CF2 to prevent mixing up the 
files. The SYS file (CF1) must be installed before CF2 or the update will not work.  
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DMU-2000_V008_2-25-10.zip 

        

                

DMU-2000_V009_2-25-10.zip 

If you have version 

03xx or 04xx,

 you must 

create two cards; one with 

CF1_V008-sys 

and 

another with 

CF2_V421-app

.  

 

 

Open the 

CF1

 folder and copy two files to 

CF card 1

 

 

 

 

 

Open the 

CF2 

folder and copy two files to 

CF card 2

 

 

 

If you have version 

05xx,

 you must create two 

cards; one with 

CF1_V009-sys 

and another 

with 

CF2_V511-app

.  

 

 

Open the 

CF1

 folder and copy two files to 

CF card 1

 

 

 

 

 

Open the 

CF2 

folder and copy two files to 

CF card 2

 

 

 