background image

 

Vertex™ 

Filter Sock Instruction Manual

   

           

©Vertex Aquaristik ™ 2018

  

 

 

 

P

ag

e

 

-

 

inner  tube  diameter  to  ensure  no  media  particles will get  through.  Push  the  foam  disc  down 
using a large rod.  

5-

 

Fill the inner chamber assembly with media 

6-

 

Assemble  the  upper  perforated  plate  over  the  inner  chamber  and  fasten  in  place  using  the 
onboard Titanium Screw. If the foam dis is required, it is best to place over the inner tube prior 
to installing the upper perforated plate. Refrain from over tightening which can possible damage 
the threading. Damaged threading, if cause by negligence or improper installation, will not be 
covered under warranty.  

7-

 

Place the inner chamber assembly back inside the unit.  

8-

 

Place the lid over the inner tube assembly and ensure alignment with the middle tube port of 
the lid. Once close, the O-ring on the tube will create a sealed connection. Small amount of food 
grade silicone lubrication can be used to ensure proper seal. 

9-

 

Close the lid turning clockwise. Make sure the middle tube is being properly driven inside the 
port.  

10-

 

Vertex  ™  Rx

-U  reactors  are  fit  to  be  utilized  both  in  sump  and/or with  external  applications. 

Choose the reactors location carefully and measure the length of tubing required to install your 
reactor.  

11-

 

Rx-U reactors are designed to be either hard plumbed to your system or used remotely via hose 
or soft tubing. A pair of barbed hose connections are supplied to accommodate such installation 
and use.  

12-

 

If  you  desire  to  use  the  reactor  remotely,  use  PVC  cement  to  permanently  glue  the  barbed 
connections to the union and union ball valve. Use proper sized soft tubing or a hose. Inserting 
the end of the hose in hot water for a few seconds will make the material softer and installation 
easier. Ultimately, small amounts of food grade lubrication can be used to slip the hose over. 
Use hose clamps to secure the connections.  

13-

 

Check the lid and all the connections to make sure they are properly installed and seated. 

14-

 

Attached  the  feed-line  to  the  ball  valve  connection  to  avoid  pressurizing  the  reactor.  Excess 
pressure can damage our reactor. Such damages are not covered under warranty.  

15-

 

Attach the exit line to the union connection. Find an adequate place for the exit line in your sump 
or aquarium. 

16-

 

Open the valve and let the reactor fill with water. Once filled, close the valve for a few seconds 
to let the media settle.  

17-

 

Once  the  media  is  settled,  slowly  open  the  valve  and  adjust  the  flow  rate  according  to  the 

media’s requirement and/or manufacturers

 guidelines.  

 

Warning:  To  avoid  damage  to  property,  livestock  and/or  personal  injury,  please  follow  all  these 

instructions and/or consult with a professional. Vertex Aquaristik™ will not be held accountable for any 

damaged the misuse and/or improper installation of the unit may cause.  

Содержание Rx-U+ Series

Страница 1: ... the unit and keep all original packaging as well as proof of purchase Any damages to the unit during transport are not covered under warranty and must be claimed with the forwarder at the time of receiving the product 2 After proper inspection clean the unit with a damp cloth using RO water to ensure removal of any oils and or chemicals used during the manufacturing process 3 Rinse media with RO ...

Страница 2: ...mbed to your system or used remotely via hose or soft tubing A pair of barbed hose connections are supplied to accommodate such installation and use 12 If you desire to use the reactor remotely use PVC cement to permanently glue the barbed connections to the union and union ball valve Use proper sized soft tubing or a hose Inserting the end of the hose in hot water for a few seconds will make the ...

Страница 3: ...r amount of flow and or media required contact the manufacturer directly Any media will be exhausted in time and needs to be exchanged or replenished For proper media renewal regimens please consult with the media manufacturer Maintenance After extended operation time or when deemed necessary lubrication can be applied on the O rings Only use food grade silicone grease The unit can be fully disass...

Страница 4: ...lated issues should be handled at the point of purchase location by trained staff Please contact your dealer for warranty or any other service or maintenance the unit might require Pay attention to all the warnings and pointers noted in this guide and use common sense To avoid damage to property livestock or personal injury please follow all these instructions or consult with a professional Vertex...

Страница 5: ...egarding this or any other Vertex Aquaristik products please either consult with your dealer or use any of the following resources Website www vertexaquaristik com E mail info vertextechnologies net By Phone 1 844 254 1776 Monday Friday 9am to 6pm PST By Mail 5445 Oceanus Dr 107 Huntington Beach CA 92649 USA ...

Отзывы: