Versiton SF70460MP Скачать руководство пользователя страница 31

-31- 

>SNMP View Delete <index> 

>SNMP View Lookup [<index>] 

>SNMP Access Add <group_name> <security_model> <security_level> [<read_view_name>] 

[<write_view_name>] 

>SNMP Access Delete <index> 

>SNMP Access Lookup [<index>] 

 

Using Web Interface 

 

The commands supports configuration for: 

 

-

 

Basic system configuration for SNMP v1 and SNMP v2c 

-

 

Basic system configuration for SNMP v1 trap, SNMP v2c trap and SNMP v3 trap 

-

 

Communities that permit to access to SNMPv3 agent 

-

 

USM (User-based Security Model) user table for SNMPv3 

-

 

VACM (View-based Access Control Model) Viewer table for SNMPv3 

-

 

Group table for SNMPv3 

-

 

Accesses group table for SNMPv3 

 

3.6 SNMP MIBs 

The switch provides the following SNMP MIBs: 

 

-

 

RFC 1213 - MIB II 

-

 

RFC 2674 - QBridge MIB (VLAN MIB) 

-

 

RFC 2819 - RMON (Group 1, 2. 3 & 9) 

-

 

RFC 2863 - Interface Group (IF) MIB 

-

 

RFC 3411 - SNMP Management Frameworks 

-

 

RFC 3414 - User Based Security Model (USM) 

-

 

RFC 3415 - View Based Access Control Model (VACM) 

-

 

RFC 3621 - Power Ethernet MIB 

-

 

RFC 3635 - EtherLike MIB 

-

 

RFC 3636 - 802.3 Medium Attachment Units (MAUs) MIB 

-

 

RFC 4133 - Entity MIB 

Содержание SF70460MP

Страница 1: ...1 SF70460MP 4 Port 10 100 1000Base Managed PoE PoE Switch Installation Guide v1 00 June 2016 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com...

Страница 2: ...ement is subsequent to receipt of your product at our facility and our diagnostic evaluation and review of the unit Advance replacements are not provided as part of the warranty coverage This warranty...

Страница 3: ...may not cause harmful interference and 2 This device must accept any interference received including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates comp...

Страница 4: ...ng UTP Connections 20 2 9 Making Fiber Connection 21 2 10 Making PoE PSE Connections PoE Model 23 1306B2 11 LED Indication 24 3 Manage the Device 26 3 1 IP Address Password 26 3 2 Configuring IP Addre...

Страница 5: ...5 5 Redundant Ring Application 40 5 1 Auto Multi Ring Technology for 4 Port Switch Mode 40 5 2 Redundant Ring Applications with industrial standard RSTP protocol 41...

Страница 6: ...he following network ports Two 10 100 1000Mbps Gigabit copper ports Two dual speed SFP slots for 100Base FX 1000Base X The device features the following function modes Dual media converter mode Dual m...

Страница 7: ...ure and configured port link down Green Ethernet power saving 802 3az Energy Efficient Ethernet EEE support Optional high power PoE PSE function on copper ports Management HTTP HTTPS SSHv2 CLI telnet...

Страница 8: ...8 1 2 Product Panels The following figure illustrates the front panel and rear panel of the device Front panel PoE Model Front panel Standard Model...

Страница 9: ...3u 1000Base T Connectors Shielded RJ 45 jacks Pin assignments Auto MDI MDI X detection Configuration Auto negotiation or software control Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full...

Страница 10: ...ength 9 6K bytes IP Multicast groups 8192 supported Flow control IEEE 802 3x pause frame base for full duplex operation Back pressure for half duplex operation Terminal Block Connector DC power input...

Страница 11: ...Panel mounting optional Environmental Operating Temperature Typical 30 75 Storage Temperature 40 85 Relative Humidity 5 90 non condensing Electrical Approvals FCC Part 15 rule Class A CE EMC CISPR11...

Страница 12: ...ug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The pro...

Страница 13: ...re The steps to mount the switch onto a DIN rail are 1 Install the mounting bracket onto the switch unit as shown below 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a li...

Страница 14: ...14 Dimensions...

Страница 15: ...ng bracket supports mounting the switch on a flat surface securely The mounting steps are 1 Install the mounting bracket on the switch unit 2 Screw the bracket on the switch unit 3 Screw the switch un...

Страница 16: ...16 Dimensions...

Страница 17: ...ecifications Applications Power per PSE port DC working voltage General 8V 60VDC PoE 15 4W max 45V 57VDC Typical 48V High power PoE PoE 35W max 45V 57VDC 52V up for 35W WARNING The 48VDC power supply...

Страница 18: ...Vdc connections Alarm Relay output pins and logic Pin 4 5 Alarm relay output NO Normal Open contacts Open normal Shorted Alarm NO NO Pin 5 6 Alarm relay output NC Normal Closed contacts Shorted normal...

Страница 19: ...the switch without turning off the power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are...

Страница 20: ...e for MDI to MDI X connection It simplifies the cable installation Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethe...

Страница 21: ...ber transceiver into SFP slot the steps are 1 Turn off the power to the switch 2 Insert the SFP fiber transceiver into the SFP slot Normally a bail is provided for every SFP transceiver Hold the bail...

Страница 22: ...s for configuring port speed via software for SFP Port 9 and Port 10 The options are Auto Auto detection for the type of the installed SFP transceiver by reading DDM data 100Mbps transceiver Non auto...

Страница 23: ...airs 4 5 7 8 of the cable The maximum distance supported is 100 meters 3 The power voltage supplied to the switch must be within the range as specified in section 2 5 to make the PoE function work pro...

Страница 24: ...itialization and diagnostics G Y BLINK Initialization completed with diagnostic error or system error found during normal operation Green ON Initialization completed with no error operating in 2MC mod...

Страница 25: ...rt link status Green ON Port link is established No traffic Green BLINK Port link is up and there is traffic OFF Port link is down Port 3 Port 4 SPEED_LED Port speed link status Green ON A 1000Mbps li...

Страница 26: ...2 255 255 255 0 The device uses local authentication instead of RADIUS authentication with factory defaults Fixed Username admin Default password No password is required with factory default However t...

Страница 27: ...sers Delete user_name Refer to Operation manual for telnet management 3 3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address for th...

Страница 28: ...28 No password is required Click OK to login into the device Web Page after a Successful Login Select Configuration System IP to configure IP address Configuration Description...

Страница 29: ...s enabled DUT will relay DNS requests to the current configured DNS server on DUT and reply as a DNS resolver to the client device on the network Save Click to save the changes Reset Click to undo any...

Страница 30: ...tination ipv6_addr SNMP Trap Authentication Failure enable disable SNMP Trap Link up enable disable SNMP Trap Inform Mode enable disable SNMP Trap Inform Timeout timeout SNMP Trap Inform Retry Times r...

Страница 31: ...to access to SNMPv3 agent USM User based Security Model user table for SNMPv3 VACM View based Access Control Model Viewer table for SNMPv3 Group table for SNMPv3 Accesses group table for SNMPv3 3 6 S...

Страница 32: ...tication Client MIB RFC 5519 Multicast Group Membership Discovery MGMD MIB IEEE 802 1 MSTP MIB IEEE 802 1AB LLDP MIB IEEE 802 1X Port Access Entity PAE MIB TIA 1057 LLDP Media Endpoint Discovery MED M...

Страница 33: ...rating Mode Configuration One setting switch SW is provided for operating mode configuration as shown below The functions of the SW switch settings are SW1 1 Hardware 1 The operating mode is determine...

Страница 34: ...LFPT function is disabled 1 SW ON 0 SW OFF LFPT Link Fault Pass Through function LFPT Function A media converter performs frame forwarding between two port segments The port segments may be different...

Страница 35: ...Software configuration F2F MC Management configuration 1 Available Available LFPT SW4 setting Software configuration Port operating mode Auto for all ports Software configuration IGMP Disabled Softwa...

Страница 36: ...s dual media converter mode As configured the device becomes two media converters in one box Port 1 and Port 3 are ports of MC1 converter Port 2 and Port 4 are ports of MC2 converter Both media conver...

Страница 37: ...Port 2 have no logic connection to Port 3 and Port 4 under this mode Multi mode fiber MMF to single mode fiber SMF conversion is the most popular application with this operating mode LFPT function op...

Страница 38: ...uplink Trunk port P3 4 is LACP compliant Both P3 and P4 are operating at the same time normally When any is in link fault the other will take over the transmission duty for both MC1 and MC2 LFPT func...

Страница 39: ...TP HTTPS SSHv2 CLI telnet CLI console SNMP v1 v2c v3 RMON DHCP DHCPv6 client DHCP relay DNS client NTPv4 IPv6 support System Syslog Configuration down upload Software upload Security functions NAS 802...

Страница 40: ...tch It is also able to work with RSTP support concurrently in the switch Some basic information is Supports up to two rings in one switch Supports ring member status monitoring for up to 100 member sw...

Страница 41: ...standard RSTP protocol It also can be done to support a ring connection using industrial standard RSTP function and establish a backup path In case that any link failure occurs the backup path can li...

Отзывы: