Power Supply Control
Individual voltage outputs can be disabled using the disable lines on the J5 connector. The J5
connector is a series of four two-pin, 5.08 mm screw terminals accepting AWG 16-14 insulated
wire.
All output voltages are on by default. To turn off a voltage, tie the voltage disable pin directly to
ground. Disabling the +5V output turns off all outputs.
Table 5: Power Supply Control Connector Pinout
J5
Pin
Signal
5 +12V
Disable
6 -12V
Disable
7 +5V
Disable
8 Ground
Efficiency and Derating
Figure 10. Power Supply Efficiency over V