EPM-15 Reference Manual
22
System Features
Power Supply
P
OWER
C
ONNECTORS
Main power is applied to the EPM-15 through a 10-pin polarized connector, with mating
connector Berg 69176-010 (Housing) + Berg 47715-000 (Pins). See the table below for connector
pinout and Figure 7 for location information.
Warning!
To prevent severe and possibly irreparable damage to the system, it is critical that
the power connectors are wired correctly. Make sure to use all +5VDC pins and all
ground pins to prevent excess voltage drop. Some manufacturers include a pin-1
indicator on the crimp housing that corresponds to pin-10 of the pinout shown in
Figure 11.
Table 4: Main Power Connector Pinout
J9
Pin
Signal
Name
Description
1 GND
Ground
2 +5VDC Power
Input
3 GND
Ground
4 +12VDC Power
Input
5 GND
Ground
6 -12VDC Power
Input
7 +3.3VDC Power
Input
8 +5VDC Power
Input
9 GND
Ground
10 +5VDC
Power
Input
Figure 11 shows the VersaLogic standard pin numbering for this type of 10-pin power connector
and the corresponding mating connector.
Figure 11. J9 and CBR-1008 Pin Numbering
4
4
2
4
6
8
10
1
3
5
7
9
J9
CBR-1008
1 3
5 7
9
2 4
6 8
10
Some manufacturers include
a pin-1 indicator that
corresponds to pin-10 of the
power connector pinout