Thermal Considerations
Bengal (VL-EPMe-30) Reference Manual
57
Figure 21. Installing the Passive Heat Sink
Installing the Heat Sink Fan
Install the heat sink fan (VL-HDW-407) using these steps:
1. Position the fan assembly
Using Figure 22 as a guide, align the mounting holes of the heat sink fan with the four
holes in the passive heat sink. Position the fan so that its power cable is on the side
nearest the J24 CPU fan connector. The CPU fan connector is located between the two
Mini DisplayPort connectors (see Figure 6.)
2. Secure the fan to the heat sink
Affix the heat sink fan using four M3 pan head screws.
Using a torque screwdriver, tighten the screws to 4.0 inch-pounds.
3. Connect power to the fan
Connect the fan’s power cable to the J24 CPU fan connector on the Bengal board.
Figure 22. Installing the Heat Sink Fan