15
9880021100-CU 30P VERONA PRO 040413040413
GAS SUPPLY
Installation of this range must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1 latest edition.
In Canada the range must be installed in accordance with the current CGA
Standard CAN/CGA-B149 – Installation Codes for Gas Burning Appliances
and Equipment and/or local codes.
GAS SUPPLY CONNECTION: (SEE FIGURE 15)
A TRAINED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST
MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance
shall be conducted by the installer according to the instructions given
in section (h).
Natural gas supply line must have a natural service regulator. Inlet pressure
to this appliance should be reduced to a maximum of 7 inches water column.
Liquefied Petroleum L.P. / Propane gas supply line must have a L.P. gas
pressure regulator. Inlet pressure to this appliance should be reduced to a
maximum of 14 inches water column.
Inlet pressure in excess of 14 in. W.C. can damage the appliance pressure
regulator, or other gas components in this appliance and can result in a gas
leak.
a) A gas cut-off valve should be put in an accessible location in the supply
line ahead of the range, for turning on and turning off gas supply. If hob is
to be connected to house piping with flexible or semi-rigid metal
connectors for gas appliances, connectors nuts must not be connected
directly to pipe threads. The connectors must be installed with adapters
provided with the connector.
b) The house piping and/or range connector used to connect the hob to the
main gas supply must be clean, free of metal shavings rust, dirt and liquids
(oil or water). Dirt, etc in the supply lines can work its way into the range
manifold and in turn cause failure of the gas valves or controls and clog
burners and/or pilot orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY DOOR HANDLES OR
BACKGUARD.
c) Turn off all pilots and main gas valve of other gas appliances.
d) Turn off main gas valve at meter.
e) Before connecting range apply pipe thread compound approved for LPG
to all threads.
Содержание VEFSGG30
Страница 22: ...22 9880021100 CU 30P VERONA PRO 040413040413 Fig n 11 Fig n 12 ...
Страница 23: ...23 9880021100 CU 30P VERONA PRO 040413040413 Fig n 13 Fig n 14 ...
Страница 24: ...24 9880021100 CU 30P VERONA PRO 040413040413 Fig n 15 Fig n 16 ...
Страница 25: ...25 9880021100 CU 30P VERONA PRO 040413040413 Fig n 17 Fig n 18 A Fig n 18 B Fig n 19 ...