3-Wire Conduit Installation
(See Figure 3.5)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 4 fixing
Screws
(Figure 3.4).
2. Check the correct positioning of the
Conduit Bracket
as per
figure 3.5.
3. Feed 1/2” (1.3 cm) trade size
Conduit
through the hole in the
Conduit Bracket
and secure to the
Conduit Bracket
with a
Conduit Clamp
.
4. Plug the terminal holes of conductors.
The
Neutral or Ground Wire
must be connected to the neutral
terminal located in the center of
Terminal Block
.
The
Power Wires
must be connected to the outside terminals.
5. Plug washers and tighten nuts securely.
Do not remove
Ground strap
.
6. Reassemble the
Terminal Block Access Plate
on the back of
the range by screwing the 4 fixing
Screws
(Figure 3.4).
4-Wire Conduit Installation
(See Figure 3.6)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 4 fixing
Screws
(Figure 3.4).
2. Check the correct positioning of the
Conduit Bracket
as per
figure 3.6.
3. Feed 1/2” (1.3 cm) trade size
Conduit
through the hole in the
Conduit Bracket
and secure to the
Conduit Bracket
with a
Conduit Clamp
.
4. Remove the 3 wire terminal nuts and washers from the
Termi-
nal Block
.
5. Remove the
Ground Strap
from the frame of range and termi-
nal by removing its screw and cutting it as shown in Figure 3.6.
6. Plug the terminal holes of conductors.
The
Neutral Wire
must be connected to the neutral terminal
located in the center of
Terminal Block
; the
Power Wires
must
be connected to the outside terminals; the
Ground Wire
must
be attached to the frame of range by using the (Ground) identi-
fied
Grounding Screw
.
7. Plug washers and tighten nuts securely.
8. Reassemble the
Terminal Block Access Plate
on the back of
the range by screwing the 4 fixing
Screws
(Figure 3.4).
Terminal Block
Ground strap
Neutral Wire
Power Wires
Conduit
Conduit Clamp
B
Power Cord
Bracket
A
: D=1” 9/64 (29 mm)
B
: D=7/8” (22.5 mm)
A
Terminal Block
Cut Ground Strap
Neutral Wire
Power Wires
Conduit
Conduit Clamp
Grounding Wire
Grounding
Screw
B
Power Cord
Bracket
A
: D=1” 9/64 (29 mm)
B
: D=7/8” (22.5 mm)
A
Terminal Block
Access Plate
Screws
Screws
Fig. 3.4
Fig. 3.5
Fig. 3.6