installation

1

PROXIMITY TO SIDE CABINETS

1.  This range may be installed directly adjacent to existing 36” 

(914 mm) high base cabinets.

 

Range dimensions:

• 

width: 35 7/8” (911 mm) (width of cabinetry opening 36”, 

914 mm)

• 

depth: 25” 1/4 (641 mm)

• 

height (without backguard): MIN 35” 3/8 (898 mm) - MAX 

37” 1/4 (946 mm)

• 

backguard (height): 3” (76 mm)

• 

island trim (height): level with cooking hob

 

Note: the island trim is supplied with the appliance while the 

backguard can be purchased as a separate kit.

 

Grounded outlet:

 The electric cord with 4-prong ground plug 

(NEMA 14-50P) shall have a minimum length of 48” (1220 

mm) beyond the back of the appliance. The grounded outlet 

should  be  located  7/32”  (6  mm)  from  the  left  or  right  side 

for 35” 7/16 (899 mm) towards the centre of range; from 8” 

1/8 (206.5 mm) to 10” 3/32 (256.5 mm) [depending on feet 

regulation] from the floor.

2.  The  range  CANNOT  be  installed  directly  adjacent  to 

sidewalls, tall cabinets, tall appliances, or other side vertical 

surfaces above 36” (914 mm) high.

 

There must be a minimum of 2” (50 mm) side clearance from 

the range to such combustible surfaces TO THE LEFT or TO 

THE RIGHT above the 36” (914 mm) high countertop.

 

IMPORTANT: One side (left or right) above the 36” (914 

mm) high countertop must always be kept clear.

3. 

The maximum upper cabinet depth recommended is 13” (330 

mm). Wall cabinet above the range must be a minimum of 30” 

(762 mm) (see also “Additional information about minimum 

clearance  from  cooking  surface  to  overhead  cabinet  or 

ventilation  hood”  here  below)  above  the  countertop  for  a 

width of minimum 36” (911 mm): it has to be centered with 

the  range.  Side  wall  cabinets  above  the  range  must  be  a 

minimum of 18” (457 mm) above the countertop.

Additional  information  about  minimum  clearance  from 

cooking surface to overhead cabinet or ventilation hood:

• 

30” (762 mm), overhead cabinet centered above the cooktop 

(combustible/unprotected) (see also notes #1, #2)

• 

24” (610 mm), overhead cabinet centered above the cooktop 

(non-combustible/protected) (see also notes #1, #2)

• 

24” (610 mm), ventilation hood centered above the cooking 

surface (see also notes #3)

Note #1

To eliminate the risk of burns or fire by reaching over heated surface 

units, cabinet storage space located above the surface units 

should be avoided. If cabinet storage is to be provided, the risk can 

be reduced by installing a rangehood that projects horizontally a 

minimum of 5 “ (127mm) beyond the bottom of the cabinets.
Note #2

30” (762mm) minimum clearance between the top of the cooking 

surface and the bottom of an unprotected wood or metal cabinet; 

or 24” (610mm) minimum when bottom of wood or metal cabinet 

is protected by not less than 1/4” thick flame retardant millboard 

covered with not less than No. 28 MSG sheet steel, 0.015” (0.4 

mm)  thick  stainless  steel,  0.024”  (0.6  mm)  thick  aluminum,  or 

0.020” (0.5 mm) thick copper.
Note #3

Refer to local/national codes for ventilation requirements.

Fig. 1.1a

Fig. 1.1b

3”

(76 mm)

MIN 35” 3/8 (898 mm) MAX 37” 1/4 (946 mm)

36”

(914 mm)

36”

(914 mm)

Backguard

Island trim

25” 1/4

(641 mm)

25” 1/4

(641 mm)

MIN 35” 3/8 (898 mm) MAX 37” 1/4 (946 mm)

Содержание VDFSEE365 Series

Страница 1: ...nded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Electrical installation must be in accordance with the Nationa...

Страница 2: ...2...

Страница 3: ...ached to the back of the range Slide range forward To verify the anti tip bracket is installed and engaged Tip Over Hazard Anti tip bracket Adjustable bracket assembly to be fixed to the back of the r...

Страница 4: ...FIED INSTALLER Installation must conform with local codes Improper installation adjustment alteration services or maintenance can cause injury or property damage Consult a qualified installer or a ser...

Страница 5: ...a rolling lift jack should be used Do not push against any of the edges of the range in an attempt to slide it into or out of the installation Pushing or pulling a range rather than using a lift jack...

Страница 6: ...e from cooking surface to overhead cabinet or ventilation hood here below above the countertop for a width of minimum 36 911 mm it has to be centered with the range Side wall cabinets above the range...

Страница 7: ...purchased as a separate kit If replacing the island trim with the backguard assemble it by using the same screws spacers used for fixing the island trim figures 1 3a 1 3b ELECTRIC CONNECTION Fig 1 2 D...

Страница 8: ...ximum G 20 minimum 500 minimum H 0 0 A C A B G E D F A A B G E D F C H H Maximum height of cabinetry immediately adjacent to the range from floor to countertop Depending on the height of the feet adju...

Страница 9: ...6 Fig 1 6 LEVELLING THE COOKER The cooker may be levelled by screwing the lower ends of the feet IN or OUT fig 1 7 It is important to observe the directions of figure 1 7 1 31 32 50 mm 0 mm 0 Fig 1 7...

Страница 10: ...p bracket and ensure they are properly fitted together to prevent the range from tipping To fit the anti tip bracket 1 Thread the bolt through the adjustable bracket and fix in place using the two sup...

Страница 11: ...e two nuts are well tightened after any adjustments IMPORTANT Use the proper screws to fix the stability bracket in place according to the type of material on the floor and or wall Before drilling and...

Страница 12: ...sary Voltage and Power Consumption AC 120 240 V 60 Hz 11150 W MAX 46 63 A MAX AC 120 208 V 60 Hz 8380 W MAX 40 30 A MAX ELECTRICAL CONNECTION WITH POWER CORD Use a 3 wire power supply cord kit rated f...

Страница 13: ...n of the circuit breaker Mark it for easy reference 4 Wire Installation fig 3 2 1 Loosen the L1 L2 and neutral screws 2 Mount the conduit fitting to the 1 1 8 29mm hole in the strain relief bracket 3...

Страница 14: ...Tl1 LF S2 TS ELECTRIC DIAGRAM KEY Tl1 Cooling fan Thermolimitator CF Cooling fan TS Security thermal overload M Terminal block T Hearth plant OVEN F1 Oven switch TM Oven thermostat PR Programmer TL Th...

Страница 15: ...15...

Страница 16: ...rors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without prior notice...

Отзывы: