Page 1616 of
18
Web Console Configuration
Here you can verify the connections & settings. Connect a PC to the Converter. The operating system can be
Windows 95, 98, ME, XP, 2000. The “Hyper Terminal” utility should be installed on your PC (see Figure 4.1).
Connect the RS232 port of the Converter to the PC COM port & the Ethernet ( RJ45 ) port of the Converter to
the PC’s LAN port.
Hyper Terminal for TCP/IP WinSock
Initiate a Hyper Terminal from the Start Menu in Windows (see Figure 4.1), give a terminal name, choose an
icon, and press “OK” button (see Figure 4.2).
Figure 4.1 Figure 4.2
Select “TCP/IP (Winsock)” option at the “Connect using:” field (see Figure 4.3)
Figure 4.3 Figure 4.4
After “OK” button is pressed, Figure 4.4 appears. Enter the converter’s IP address (e.g. 192.168.0.10) at the
“Host address:” field and the Socket port number set for the Serial Port 1 at the “Port number:” field (e.g 4660).
(The Socket type of the Serial Port 1 should be “TCP Server”.)