Warranty 

The Vernier Digital Radiation Monitor is manufactured by a third party, and is 

subject to their warranty. 
This product is warranted to the original owner to be free from defects in materials 

and workmanship for one year from the date of purchase with the exception of the 

Geiger-Mueller tube, which is warranted for 90 days, and with the exception of the 

battery, which is not included in this warranty. Vernier Software. will, at its own 

discretion, repair or replace this instrument if it fails to operate properly within this 

warranty period unless the warranty has been voided by any of the following 

circumstances: misuse, abuse, or neglect of this instrument voids this warranty; 

modification or repair of this instrument by anyone other than Vernier Software 

voids this warranty; contamination of this instrument with radioactive materials 

voids this warranty. Contaminated instruments will not be accepted for servicing at 

our repair facility. 
The user is responsible for determining the suitability of this product for his or her 

intended application. The user assumes all risk and liability connected with such use. 

Vernier Software is not responsible for incidental or consequential damages arising 

from the use of this instrument. 

 
 
 
 
 
 
 
 
 

 

Vernier Software & Technology 

13979 S.W. Millikan Way 

 Beaverton, OR 97005-2886 

Toll Free (888) 837-6437 

 (503) 277-2299 

 FAX (503) 277-2440  

[email protected] 

 www.vernier.com 

 

Rev. 1/31/08 
Logger

 Pro

, Vernier LabPro, and other marks shown are our registered trademarks in the United States. 

CBL 2, TI-GRAPH LINK, and TI Connect are trademarks of Texas Instruments. 
All other marks not owned by us that appear herein are the property of their respective owners, who may or may not be 
affiliated with, connected to, or sponsored by us.  

 

Printed on recycled paper.

 

 

Содержание DRM-BTD

Страница 1: ...d gamma radiation With the Digital Radiation Monitor you can Monitor possible radiation exposure while working near radionuclides Ensure compliance with regulatory standards Check for leakage from X r...

Страница 2: ...indicate low battery voltage An hourglass C appears to the left of the numeric display during a timed count TOTAL D appears when the Digital Radiation Monitor is in Total mode X1000 E appears when the...

Страница 3: ...s microsieverts per hour and counts per second To switch between conventional and SI units use the Utility Menu See The Utility Menu in this chapter Starting the Digital Radiation Monitor Be sure that...

Страница 4: ...o determine the radiation level Mode Regular Range X1000 Range mR hr 0 001 110 NA Sv hr 0 01 1100 NA CPM 0 9999 10 000 350 000 displayed as 10 00 350 with X1000 indicator CPS 0 3500 NA Total Timer 0 9...

Страница 5: ...t In some locations you may want to take a longer count for example 12 hours If you need to determine whether there is prior contamination take averages in several locations and compare the averages 1...

Страница 6: ...or poor connection Install and firmly connect a new 9 volt battery broken LCD If count light and audio work the LCD may need to be replaced Display works but no counts are registered damaged Geiger t...

Страница 7: ...roton Neutron A hydrogen atom has one electron and one proton The most common isotope has no neutrons and is stable Tritium is a radioactive isotope of hydrogen It has two neutrons in its nucleus 14 T...

Страница 8: ...mposition altitude and other factors For example normal background at 10 000 feet might be double that at sea level On an airplane the radiation at 35 000 to 40 000 feet may be as much as 30 to 50 tim...

Страница 9: ...contamination of this instrument with radioactive materials voids this warranty Contaminated instruments will not be accepted for servicing at our repair facility The user is responsible for determini...