background image

5

27D8851

VWFST Series Vented Gas Log Set

Chimney Height

Flue Opening

6'

64 sq in

8'

64 sq in

10'

64 sq in

15'

51 sq in

20'

51 sq in

30'

51 sq in

GETTING STARTED 

MAKE SURE YOU HAVE RECEIVED ALL PARTS

Check your packing list to verify that all listed parts have 

been received. You should have the following:

BURNER - GRATE ASSEMBLY 18", 24"

 

  Burner and Grate Weldment Assembly 

• 

Lava Rocks (x2) 

•  

Reducer 

•  

Glowing Embers (Rock Wool) 

•  

Damper Clamp 

•  

Injector

•  

Installation /Operating Instructions 

•  

Vermiculite  

•  

3/8" Aluminum Tube with 3/8" 90° Elbow, 1/2" to 

3/8" tube fitting

•  

Shield Plate 

 

 

 

 

 

18" OR 24" CERAMIC FIBER OR REFRACTORY 

LOGS 

  Individual Logs 

•  

Installation Instructions

Carefully inspect the contents for shipping damage. If any 

parts  are  missing  or  damaged,  immediately  inform  the 

dealer from whom you purchased the appliance. 

Do not 

attempt to install any part of the appliance unless you 

have all parts in good condition.

ITEMS REQUIRED FOR INSTALLATION

Ensure that the following items are available before pro-

ceeding with installation:

•  

External regulator (for propane/L.P.G. only) 

  Shutoff valve 

   Pipe wrench

•  

Piping which complies with local codes 

•  

Drill with masonry bit (for mounting to the floor) 

 

•  

Pipe sealant approved for use with propane/L.P.G. 

(Resistant to sulfur compounds)

MINIMUM FREE OPENING AREA OF CHIM-

NEY DAMPER FOR VENTING

MINIMUM CHIMNEY HEIGHT AND FLUE 

OPENING 

W

ARNING

  Handle the gas log burner assembly by 

the grate only. Do not pick the unit up by 

the burner. 

  Gloves are recommended when handling 

ceramic  fiber  logs  to  prevent  skin 

irritation  from  loose  fibers.  Logs  are 

fragile — handle with care.

W

ARNING

The  fireplace  and  gas  logs  function  as 

a  system.  If  the  fireplace  is  not  drafting 

properly and spilling into the room (check 

with a match or a smoke stick), reposition 

the damper clamp until the positive draft is 

obtained by opening the damper. If negative 

pressure in home prevents having a positive 

draft, contact your dealer for assistance. 

Содержание VWF18STN

Страница 1: ...o not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department In...

Страница 2: ...e Volcanic Rock 14 VWF18ST VWF24ST Log Placement 14 Operating Instructions 16 SPK and CVTHL kits 16 For Your Safety Read Before Lighting 16 Manual Control SPK 16 Hi Lo control CVTHL 16 Millivolt Contr...

Страница 3: ...damper be permanently removed or welded in the full open position In addition a naturally vented gas log may not be installed in a bedroom or bathroom in the Commonwealth of Massachusetts Flex line in...

Страница 4: ...nown as wellhead gas Model A B C D VWF18STN 20 20 18 16 VWF24STN 26 26 18 16 Figure 1 Minimum Hearth Dimensions GAS pressures Natural Propane LP Max Gas Inlet Pressure 10 0 w c 13 0 w c Min Gas Inlet...

Страница 5: ...e all parts in good condition ITEMS REQUIRED FOR INSTALLATION Ensure that the following items are available before pro ceeding with installation External regulator for propane L P G only Shutoff valve...

Страница 6: ...replace firebox Depth of fireplace firebox Refer to Table Figure 2 NOTE Noncombustible material such as refractory brick may be used to line the floor of the fireplace in order to raise the height of...

Страница 7: ...rally vented gas log may not be installed in a bedroom or bath room in the Commonwealth of Massachusetts FP2727 damper Damper Stop Damper FP2727 Figure 3 Damper Stop Installation In compliance with AN...

Страница 8: ...ve Pilot Configured for NG Pipe Nipple Heat Shield Knob Extenders SPK LPA Kit Includes Valve Pilot Configured for LP Air Mixing Nut Brass Nut Heat Shield Knob Extenders WARNING LP sets must be install...

Страница 9: ...eries Vented Gas Log Set INSTALLATION for gas valve kits LG1052 install pilot Screw Figure 7 Install Pilot LG1052 LG1053 Heat Shield Gas Control Valve Knob Extensions Control Knob LG1053 Figure 8 Inst...

Страница 10: ...PLEMENTAL INSTRUCTIONS FOR MVVKNA INSTALLATION for gas valve kits WARNING The MANVK kit is for Natural Gas Only Injector Reducer Valve Knob Extenders Control Knob LG1054 Figure 9 MANVK LP Air Mixing I...

Страница 11: ...Bracket Natural Gas Injector Reducer Gas Control Valve Pipe Nipple Burner Fitting Figure 12 CVTHL NG Connect Valve to Unit Natural Gas only Heat Shield Control Knob LG1057 Figure 13 CVTHL LP Connect V...

Страница 12: ...a If the reading is more than 100 Millivolts and the automatic valve still does not come on replace the control b If the closed circuit reading A reading is less than 100 Millivolts determine cause fo...

Страница 13: ...flow rate BTU Hr Undue pressure loss will occur if the pipe is too small A manual shutoff valve must be installed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should...

Страница 14: ...plied with the unit To enhance the ap pearance of the Wildfire flame it is recommended to form a mound of rock wool in the center of the burner 2 to 3 high visible through the logs VWFST18ST and VWF24...

Страница 15: ...logs Left Right Curved Log 3 Left Right Curved Log 3 LG1061 Figure 18 LG1062 VWFST charred logs Left Right Split Charred Log 4 Left Right Split Charred Log 4 LG1062 Figure 19 5 Place a left right spli...

Страница 16: ...er s instructions If you cannot reach your gas supplier call the fire department B Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by ha...

Страница 17: ...OFF switch to OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP 5 From OFF position turn the gas control knob counterclockwise...

Страница 18: ...B in the safety information label If you don t smell gas go to next step MANUAL CONTROL LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exac...

Страница 19: ...g fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harm ful but may produce annoying smoke and smells as they...

Страница 20: ...tes place a match or smoke stick along the top and sides of the fireplace opening If the flame or smoke is not pulled into the fireplace then the fireplace is not venting properly At this point the da...

Страница 21: ...y by holding gently at each end Gloves are recommended when handling the log to prevent skin irritation from ceramic fibers If skin becomes irritated wash gently with soap and water Refer to manual fo...

Страница 22: ...27D0406 27D7022 27D0406 27D7022 27D0406 2 Manual Control Valve 27D0303 27D8951 27D8951 3 Millivolt Control Valve 27D8006 27D8005 4 Hi Lo Remote Control Valve 27D8954 27D8954 5 Pilot 27D0301 27D0302 20...

Страница 23: ...log parts Ref Description Qty VWF18MOST VWF24MOST 1 Bottom Left Front Log 1 2 27D7501 27D7507 2 Bottom Right Front Log 2 2 27D7502 27D7508 3 Left Right Curved Log 3 2 27D8830 27D8581 4 Top Left Right...

Страница 24: ...27D8851 24 VWFST Series Vented Gas Log Set...

Страница 25: ...25 27D8851 VWFST Series Vented Gas Log Set...

Страница 26: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Страница 27: ...ns The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox...

Страница 28: ...Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Отзывы: