5
27D8851
VWFST Series Vented Gas Log Set
Chimney Height
Flue Opening
6'
64 sq in
8'
64 sq in
10'
64 sq in
15'
51 sq in
20'
51 sq in
30'
51 sq in
GETTING STARTED
MAKE SURE YOU HAVE RECEIVED ALL PARTS
Check your packing list to verify that all listed parts have
been received. You should have the following:
BURNER - GRATE ASSEMBLY 18", 24"
•
Burner and Grate Weldment Assembly
•
Lava Rocks (x2)
•
Reducer
•
Glowing Embers (Rock Wool)
•
Damper Clamp
•
Injector
•
Installation /Operating Instructions
•
Vermiculite
•
3/8" Aluminum Tube with 3/8" 90° Elbow, 1/2" to
3/8" tube fitting
•
Shield Plate
18" OR 24" CERAMIC FIBER OR REFRACTORY
LOGS
•
Individual Logs
•
Installation Instructions
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.
Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
ITEMS REQUIRED FOR INSTALLATION
Ensure that the following items are available before pro-
ceeding with installation:
•
External regulator (for propane/L.P.G. only)
•
Shutoff valve
•
Pipe wrench
•
Piping which complies with local codes
•
Drill with masonry bit (for mounting to the floor)
•
Pipe sealant approved for use with propane/L.P.G.
(Resistant to sulfur compounds)
MINIMUM FREE OPENING AREA OF CHIM-
NEY DAMPER FOR VENTING
MINIMUM CHIMNEY HEIGHT AND FLUE
OPENING
W
ARNING
•
Handle the gas log burner assembly by
the grate only. Do not pick the unit up by
the burner.
•
Gloves are recommended when handling
ceramic fiber logs to prevent skin
irritation from loose fibers. Logs are
fragile — handle with care.
W
ARNING
The fireplace and gas logs function as
a system. If the fireplace is not drafting
properly and spilling into the room (check
with a match or a smoke stick), reposition
the damper clamp until the positive draft is
obtained by opening the damper. If negative
pressure in home prevents having a positive
draft, contact your dealer for assistance.