Vermont Castings Vigilant

2000898

connector enters the chimney.  Follow all the guidelines 
for installing a chimney connector into a freestanding 
masonry chimney, and watch these additional points:

ST695

Vigilant

above fireplace

8/8/01

VIGILANT�

Thimble Sleeve

Mantel

Bottom Heat 

Shield

Damper - closed 

and locked

ST695

Fig. 20

  In this installation the chimney connector is attached 

to the chimney above the fireplace.

•  If there is a combustible mantel or trim, check the 

stove and chimney connector clearances in the 
Clearance Chart.  Use the necessary combination of 
mantel, trim, and connector heat shields to provide 
the required clearances.

•  Double check connector clearance from the ceiling.
•  The fireplace damper must be closed and sealed 

to prevent room air from being drawn up the flue, 
reducing the draft.  However, it must be possible to 
re-open the damper to inspect or clean the chimney.

Through a fireplace

 

When installed through a fireplace opening, the chim-
ney connector goes back from the stove, enters the 
fireplace cavity, turns upward, and passes through the 
fireplace damper opening and smoke chamber, and 
finally to the chimney flue.  Watch these points:
•  If there is a combustible mantel or trim, check the 

stove and chimney connector clearances in the 
Clearance Chart.  Use the necessary combination of 
mantel, trim, and connector heat shields to provide 
the required clearances.

•  When passing the chimney connector through the 

damper opening it may be necessary to “ovalize” the 

ST696

fireplace 

flex connector

8/8/01

VIGILANT�

Flex Connector

Mantel Shield

Fireplace Adapter

Bottom 

Heat 

Shield

ST696

Fig. 21

  In this installation, the chimney connector enters the 

fireplace opening and then connects to chimney.

connector pipe.  Do not make the narrowest width 
less than 5

¹⁄₂

".

•  The damper should be removed if possible, or 

sealed in the open position if removal is impossible.

•  A seal must be provided so that room air is not 

drawn into the fireplace and up the chimney, reduc-
ing draft.  The Vermont Castings Flex Connector 
System provides a convenient method for making 
the required seal and offers a flexible stainless steel 
chimney connector which can be bent to allow pas-
sage through most narrow damper openings.

NOTE: Do not vent your Vermont Castings stove 
into a factory-built (zero-clearance) fireplace.  Zero-
clearance fireplaces and their chimneys are specifi-
cally designed as a unit for use as fireplaces. It may 
void the listing or be hazardous to adapt them for 
any other use.

Содержание Vigilant II

Страница 1: ...se SAFETY NOTICE IF THIS APPLIANCE IS NOT PROPERLY INSTALLED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTI...

Страница 2: ...ur Authorized Vermont Castings Dealer anytime you have a particular question about your stove or its performance Be assured that your cast iron Vermont Castings stove or replace has been made with the...

Страница 3: ...ption obtained under laboratory conditions and on average ef ciencies These values are based on operation in building code conforming homes under typical winter climate condi tions in New England If y...

Страница 4: ...eight due largely to a difference in temperature between the gases inside the chimney and gases out side the chimney Because gas expands when heated warm gases inside the chimney weigh less than cool...

Страница 5: ...necessary for this type of installation The chimney should extend at least 3 feet above the highest point where it passes through a roof and at least 2 feet higher than any portion of a building with...

Страница 6: ...VE OR INSERT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Chimney Size When out tted with the standard 6 150 mm ue col lar The Vigilant II Coal Stove is designed to perform well when vented through ues...

Страница 7: ...ove will be in either a parallel or a corner instal lation not both Use only the part of the chart that ap plies to your installation Note Side clearances do not apply to corner installations Measure...

Страница 8: ...mum clearance parallel installation rear heat shield For rear exiting stoves both rear and side clearances are determined by the heat from the stove provided that the connector does not pass near a co...

Страница 9: ...ed to change an unprotected wall to a protected wall allow ing the clearances given in the right half of the Clear ance Chart Wall shields should be constructed of 24 gauge or heavier sheetmetal 1 2 n...

Страница 10: ...mm Clearance to Combustibles in Front of Stove 1 A ceiling heat shield 24 610 mm in diameter and suspended 1 25 mm from the ceiling must surround the chimney con nector in installations in which the...

Страница 11: ...mm D 16 406 mm E 12 305 mm F 2 51 mm to either side of connector Fig 12 Minimum oor protection requirements ST689 oor protector must meet the same requirements as for standard legs Floor Protection f...

Страница 12: ...market which have been tested and listed speci cally for use as wall pass throughs Use only these tested and listed accessories for wall pass throughs The National Fire Protection Association NFPA has...

Страница 13: ...cessories The Removable Handle The removable handle is inserted into the front door stub or the damper handle stub when you want to open or close the doors or change the position of the damp er The ha...

Страница 14: ...Coal Stove Freestanding If the chimney connector must pass through a combustible wall to reach the chimney follow the recommendations in the Wall Pass Through sec tion ST243 thinble connection 12 13...

Страница 15: ...e Watch these points If there is a combustible mantel or trim check the stove and chimney connector clearances in the Clearance Chart Use the necessary combination of mantel trim and connector heat sh...

Страница 16: ...nformation about the ash content of the coal he sells The Vigilant II Coal Stove is designed to burn anthracite hard coal or bituminous coal soft coal Do not burn other fuels As shipped from the facto...

Страница 17: ...is between 400 and 700 F although temperatures slightly outside of this range may be expected However if tempera tures go above 700 F for extended periods decrease the air supply move the thermostat...

Страница 18: ...smaller and draft problems can result Avoid draft problems when the outside temperature is 35 F or higher by operating your stove with the damper open to keep ue temperatures high If draft problems o...

Страница 19: ...striker screw one turn and re tight ening the small locking nut Keep making adjustments slowly until the setting is right The handle should resist slightly as it is turned to the closed position and t...

Страница 20: ...e plate and then slide it toward the front of the stove so the end with the shorter offset will be behind the iron The cover in the lower reback will be inserted into the opening and pushed to the lef...

Страница 21: ...side up on a level work sur face 2 Remove the two retainer clips Carefully remove the old glass 3 Examine the gasketing Worn gasketing should be replaced Remove the old gasketing Cut new gasket ing to...

Страница 22: ...y two weeks during the heating season to determine if a soot buildup has occurred If soot has accumulated it should be removed to reduce the risk of a chimney re Fly ash carried from the fuel bed by d...

Страница 23: ...if any appear to be corroded Is the door handle adjusted so the doors close tight ly Instructions for adjusting the handle are given in the Maintenance Section Draft Problems If the draft in the chim...

Страница 24: ...m Description Part Number Item Description Part Number CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time witho...

Страница 25: ...n Cover w Handle 1601027 32 Shaker Handle 1600903 33 Ashpan 1400927 34 Ashdoor 1305045 35 Front Door Handle Assembly 5004237 36 Ashpan Bracket 1601039 37 Ashdoor Hinge 1305046 38 Ashdrop 1305044 39 Bo...

Страница 26: ...26 Vermont Castings Vigilant 2000898...

Страница 27: ...s 1 This warranty is transferable however proof of original purchase is required 2 CFM Corporation offers no warranty on chipping of enamel surfaces Inspect your Vigilant II Coal Stove prior to accept...

Страница 28: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: