VFF Vent Free Fireplace System
OPERATING INSTRUCTIONS – IPI
OPERATIONS AND INDICATIONS
System Set Up Chart
NOTE:
When using ON/OFF wall switch, the master switch, located in bottom of fi replace must be in the
ON position to perform all confi guration setup operations.
Self Diagnostics Chart
The fi replace has a self diagnostic LED on the control board enabling you to troubleshoot problems and
potentially avoid a service call. Please refer to the chart below for indicator reference.
Remote Operations
The following functions are available on the RMSC hand held remote.
NOTE: Flame height control is only available with purchase and installation of a stepper motor kit with RF
receiver
Operations
FUNCTION
OPERATION
DEFAULT
SETTING
Cold Climate Pilot On/Off
Flip the toggle switch to ON.
OFF
FUNCTION
OPERATION
Sparking error
Red LED, Flash 2 times
Flame error
Red LED, Flash 3 times
Ignition fail
Red LED, Flash 4 times
Re-ignite warning
Red LED, Flash 5 times
Pilot valve voltage error
Red LED, Flash 6 times
Main valve voltage error
Red LED, Flash 7 times
Low battery
Red LED 2.5 sec, Flash once
REMOTE FUNCTION
OPERATION
ICON
Fireplace On
Press the ON button on the transmitter.
Fireplace Off
Press the OFF button 3 times or hold the OFF button 3
seconds for memory off.
Flame Height Up
Press the ON button once to turn on the fi replace with
maximum fl ame setting.
Flame Height Down
Press the OFF button to lower the fl ame height to
medium and low.
Count Down Timer Mode
Press TIMER button to enter the timer mode. Keep
pressing the TIMER button to set the desired time or
press TIMER button to “0” to exit timer mode.
FUNCTION
OPERATION
Power Up
Flip the Master Switch to ON position to power up the system.
Fireplace On
Turn on wall switch to turn the fi replace on. NOTE: If master switch was
just switched to ON, then at fi rst use of wall switch, it may need to be
turned ON - OFF - ON to synchronize the two switch settings.
Fireplace Off
Turn the wall switch to the OFF position, or turn the ON/OFF master
switch to the OFF position
Cold
Climate
Switch
Master
Switch
®
22.0
CONTROL
BOARD