4
Vermont Castings Stratton
30004508
Specifications
EPA Emissions Rating .......................................3.0 g/hr
Range of heat output*.............. 10,100 - 7,550 BTU/hr
Maximum heat output** ..........................40,000 BTU/hr
Area heated*** ................................... up to 1,500 sq. ft.
Size of wood splits ....................18”-0” (460 - 508 mm)
Fuel Capacity......................................... 30lbs. (13.5kg)
Loading ..................................................................Front
Flue size .................................................... 8” (03 mm)
Fireplace weight ................................. 390 lbs. (177 kg)
Primary Air Control ............................................ Manual
Glass panel.......................... High-temperature ceramic
Flue exit position...................................................... Top
Blower rating...............................150 cfm. (115V, 60Hz)
*Under specific test conditions used during EPA emis-
sions standard testing.
**This value can vary depending on how the unit is
operated, and the type and moisture content of the fuel
used. Figure shown is based on maximum fuel con-
sumption obtained under laboratory conditions and on
average efficiencies.
***These values are based on operation in building-
code conforming homes under typical winter climate
conditions. If your home is of nonstandard construction
(e.g. unusually well insulated, not insulated, built under
ground, etc.) or if you live in a more severe or more
temperate climate, these figures may not apply. Since
so many variables affect performance, consult your Ver-
mont Castings’ Authorized Dealer to determine realistic
expectations for your home.
Stratton
Stratton woodburning Fireplace
Fig. 1
Stratton specifications and framing.
Gravity vent ducting may be installed on top of the fireplace to supply additional heat to the room the fireplace is in or
an adjacent room.
1/2” (13 mm)
32
6:O
”
(815 mm)
3
56
”
(79 mm)
12
36:O
”
(325 mm)
36
6:O
” (918 mm)
Rough
Opening
Height
26
56O
” (673 mm)
35
56M
” (895 mm)
16”
(406 mm)
3
3(6:O
”
(98 mm)
7
36:O
”
(207 mm)
12
36:O
”
(325 mm)
3
56
”
(79 mm)
36
56O
” (927 mm)
Rough Opening Width
Rough
Opening
Depth
11” Dia.
8” Dia.
25” (635 mm)
9”
(229 mm)
22
(6:O
”
(564 mm)
4508
Stratton Specs
5/08
5/8” (16 mm)
5/8” (16 mm)
23”
(584 mm)
51” (1295 mm)
51” (1295 mm)
72” (1829 mm)
1/2” (13 mm)
Minimum
1/2” (13 mm)
Minimum
36” (914 mm)
36
56O
” (927 mm)
Outside
Air
Electrical
Access
Outside
Air