6
2
Product Specific and General Information
Warning! Risk of Fire!
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
B. Gas Log Sets, Gas Inserts, Gas Log Light-
ers, Wood-burning Inserts
• Optional
• Vented gas log sets, gas inserts, gas log-lighters and
wood-burning inserts can be installed in this fireplace.
Follow the instructions provided with the accessory for
operation.
WARNING!
Risk of Fire or Asphyxiation!
•
DO NOT
install unvented gas logs.
• Damper must be locked open.
• Gas flame may generate fumes.
Unvented Gas Logs
CAUTION!
I
f an unvented gas appliance is installed in
the fireplace, the gas appliance must only be operated
with the fireplace glass door fully open (if included).
Only unvented gas log sets which have been found to
comply with the standard for unvented room heaters,
ANSI Z211.11.2, are to be installed in this fireplace. If
an unvented gas appliance is installed it must incorpo-
rate an automatic shutoff device, and must be installed
in accordance with the National Fuel Gas Code Z223.1,
Latest edition.
WARNING! Do Not
operate an unvented gas log set in this
fireplace with the chimney removed.
VCG Biltmore Series • SB100 Owner’s Manual • 4013-304 • Rev A • 02/19/15
A. Appliance Certification
This fireplace may be installed in sleeping rooms. This
fireplace is not approved for installation in manufactured
homes. If installed with a gas log set, provisions for the
National Fuel Gas Code must be met.
This fireplace has been tested and listed for use with the
optional components specified in this manual. These op-
tional components may be purchased separately and in-
stalled at a later date. An outside air kit, gas log set, gas
insert or gas log-lighter should be installed at the time of
fireplace installation.
This fireplace system has been tested and listed in accor-
dance with UL 127 standards by Underwriters Laboratories
Inc. for installation and operation in the United States.