6
RFSUV34 Vent-Free Heater
10001769
Run the Gas Line
If gas piping from the source to the heater location has
not been accomplished, install the required pipe. Con-
sult local plumbing code to assure proper pipe size.
The gas pipeline to be brought in through the rear or
the base of the heater.
NOTE:
The gas line connection can be made with
properly tinned 3/8" copper tubing, 1/2" rigid pipe or an
approved flex connector, then reduced to 3/8" to the
heater. Because some municipalities have some addi-
tional local codes, it is always best to consult your local
authority. Consult the current National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to pro-
vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved
fittings.
Always provide a union
when using black
iron pipe so that gas line can be easily disconnected
for burner or fan servicing. See gas specification for
pressure details and ratings.
NOTE:
If flex connector is
used, it must be kept inside of the heater. (Fig. 3)
FP297
INSTA VENT FREE
R MODEL GAS SUPPLY
8/24/96
3/8"
Nipple
1/2" Gas Supply
1/2" x 3/8" Shut-Off Valve
3/8" Nipple
3/8" Union
FP297
Fig. 3
Typical gas line installation.
Electrical Connection
When installed, the heater must be electri-
cally connected and grounded in accor-
dance with local codes or, in the absence
of local codes with the National ANSI/NFPA
No. 70.
NOTE:
110/120 electric power is required to operate
blower (fan).
Be sure to leave sufficient excess wire in case minor
adjustments are required.
Any electrical re-wiring of this fan must be
done by a qualified electrician.
Turn off all power before hook-up.
Black
White
Ground
FP394
WIRING DIAGRAM
11/20/96
Fan
Temperature
Sensor
Speed
Control
FP1025
Fig. 4
FK24 fan wiring.
Slide the Heater in Place
With the fan installed, gently slide or lift the heater to
the desired location.
Level and Secure the Heater
Make sure heater is level. Shimming may be required.
Remote Switch
Install ON/OFF switch assembly on either the rear right
or left side of the fireplace cabinet.
1. Position switch assembly onto the back of the fire-
place, then fasten two (2) screws as shown in Figure
5.
2. Attach wiring under the clips on the rear casing and
install wiring through the rear opening of the fire-
place before connecting to the valve as shown in
Figure 6.
������
�����������
Screw
(Through
existing
hole)
ON/OFF Switch
Assembly
Clips
Wiring for
Millivolt Gas
Valve
FP1585
Fig. 5
Position switch assembly on back of stove.
PILOT
ON
OFF
PILOT ADJ
LO
HI
FP1586
valve switch wire
FP1586
Fig. 6
Remote switch wiring.