Run the Gas Line 

If gas piping from the source to the heater location has 
not been accomplished, install the required pipe. Con-
sult local plumbing code to assure proper pipe size.

The gas pipeline to be brought in through the rear or 
the base of the heater.  

NOTE:

 The gas line connection can be made with 

properly tinned 3/8" copper tubing, 1/2" rigid pipe or an 
approved flex connector, then reduced to 3/8" to the 
heater. Because some municipalities have some addi-
tional local codes, it is always best to consult your local 
authority. Consult the current National Fuel Gas Code, 
ANSI Z223.1/NFPA 54.

Always check for gas leaks with a mild 
soap and water solution.  Do not use an 
open flame for leak testing.

The gas control is equipped with a captured screw type 
pressure test point, therefore it is not necessary to pro-
vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved 
fittings. 

Always provide a union

 when using black 

iron pipe so that gas line can be easily disconnected 
for burner or fan servicing.  See gas specification for 
pressure details and ratings. 

NOTE: 

If flex connector is 

used, it must be kept inside of the heater. (Fig. 3)

FP297

INSTA VENT FREE

R MODEL GAS SUPPLY 

8/24/96

3/8" 

Nipple

1/2" Gas Supply

1/2" x 3/8" Shut-Off Valve

3/8" Nipple

3/8" Union

FP297

Fig. 3

  Typical gas line installation.

Electrical Connection

When installed, the heater must be electri-
cally connected and grounded in accor-
dance with local codes or, in the absence 
of local codes with the National ANSI/NFPA 
No. 70.

NOTE:

 110/120 electric power is required to operate 

blower (fan). 
Be sure to leave sufficient excess wire in case minor 
adjustments are required.

Any electrical re-wiring of this fan must be 
done by a qualified electrician.

Turn off all power before hook-up.

Black

White

Ground

FP394

WIRING DIAGRAM

11/20/96

Fan

Temperature 

Sensor

Speed 

Control

FP1025

Fig. 4

  FK24 fan wiring.

Slide the Heater in Place

With the fan installed, gently slide or lift the heater to 
the desired location.

Level and Secure the Heater

 

Make sure heater is level.  Shimming may be required. 

Remote Switch

Install ON/OFF switch assembly on either the rear right 
or left side of the fireplace cabinet.
1.  Position switch assembly onto the back of the fire-

place, then fasten two (2) screws as shown in Figure 
5.

2.  Attach wiring under the clips on the rear casing and 

install wiring through the rear opening of the fire-
place before connecting to the valve as shown in 
Figure 6.

������
�����������

Screw

(Through 

existing 

hole)

ON/OFF Switch 

Assembly

Clips

Wiring for 

Millivolt Gas 

Valve

FP1585

Fig. 5

  Position switch assembly on back of stove.

PILOT

ON

OFF

PILOT ADJ

LO

HI

FP1586
valve switch wire

FP1586

Fig. 6

  Remote switch wiring.

Содержание RFSUV34

Страница 1: ... vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Do not touch electrical switches 2 Do not try to light any appliance 3 Do not use the phone in your building 4 Immediately call your gas sup plier from a neighbor s phone 5 Follow your gas supplier s in structions 6 If you cannot reach your gas supplier call the fire depart ment This is an unvented...

Страница 2: ...tallation Operating Instructions 3 RFSUV34 Dimensions 4 Safety Devices 5 Clearance to Combustibles 5 Locating Unit 5 Gas Supply Pressures 5 High Elevations 5 Gas Specifications 5 Run the Gas Line 6 Electrical Connection 6 Slide the Heater In Place 6 Level and Secure the Heater 6 Remote Switch 6 Operating Instructions Window Frame Removal 7 Log Installation 7 Burner Lava Rock Placement 7 First Firin...

Страница 3: ...use cancer birth de fects and other reproductive harm California Health Safety Code Sec 25249 6 FOR SAFE INSTALLATION AND OPERATION OF YOUR VENT FREE ROOM HEATER PLEASE NOTE THE FOLLOW ING 1 This heater gives off high temperatures and should be lo cated out of high traffic areas and away from furniture and draperies 2 Children and adults should be alerted to the hazards of the high surface temperat...

Страница 4: ... C K D E C N A H G F B J N M P C L 1769 RFSUV34 SPECS 9 05 Fig 1 Stove dimensions Ref RFSUV34 A 31 800 mm B 19 498 mm C 26 664 mm D 21 546 mm E 10 254 mm F 18 476 mm G 3 76 mm H 1 38 mm J 22 565 mm K 20 524 mm L 19 487 mm M 7 197 mm N 19 495 mm P 22 565 mm ...

Страница 5: ...stem by closing its individual manual shut off valve during any pressure equal to or less than 1 2 psig 3 45 kPa The heater and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPa Natural Gas LP Minimum Inlet Pressure 5 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c...

Страница 6: ...96 3 8 Nipple 1 2 Gas Supply 1 2 x 3 8 Shut Off Valve 3 8 Nipple 3 8 Union FP297 Fig 3 Typical gas line installation Electrical Connection When installed the heater must be electri cally connected and grounded in accor dance with local codes or in the absence of local codes with the National ANSI NFPA No 70 NOTE 110 120 electric power is required to operate blower fan Be sure to leave sufficient ex...

Страница 7: ...racket 4 Slip front ember log KR7 down behind the front deflector 5 Place front left log KR8 on top of burner left side Use the log s bottom holes to locate it into the left bracket log locator studs 6 Place front right log KR9 on top of burner right side Use the log s bottom holes to locate it into the right bracket log locator studs 7 Place burner lava rock on top of burner Refer to Burner Lava R...

Страница 8: ...mbustion air and can create odor Such odors will disappear over time however the condition can be alleviated by opening a window or otherwise providing additional ventilation to the area Flame Adjustment For units equipped with Hi Lo valves flame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control Fig 10 Turn counterclockwise to decrease flame...

Страница 9: ... be lit manually When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier ...

Страница 10: ...iezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot meter should read greater than 100mV Thermodisk Pilot Lights with Piezo Ignitor YES YES YES YES Pilot Stays Lit Pilot Lights Main Burner System OK START CHECK Wall switch is not turned on...

Страница 11: ...ove the window frame panel and logs exposing the burner and pilot assembly Clean all foreign materials from the top of the burner Check to make sure that burner parts are clean Visu ally inspect pilot Brush or blow away any dust or lint ac cumulation If pilot orifice is plugged disassembly may be required to remove any foreign material from the orifice or tubing To obtain proper operation it is impe...

Страница 12: ...s prices and discontinue colors and products at any time without notice RFSUV34 Ref Description RFSUV34 1 Log Set Complete 10001763 1a Log Ember Front KR7 1b Log Front Left KR8 1c Log Front Right KR9 1d Log Rear KR10 1e Log Top Left KR11 1f Log Top Right KR12 2 Lava Rock Burner Pkg 57897 3 Burner Housing Assembly w tiles Nat Prop 10001493 4a Orifice Main Burner Nat See Rating Plate for Orifice Size ...

Страница 13: ... Piezo 20000062 13 Cable Ignitor not shown 20000101 14a Valve Honeywell RN Nat 10000235 14b Valve Honeywell RP Prop 10000242 15 Manifold Tubing w Fittings 57318 16 Top Louvre Assembly 10001370 17 Frame Window Assembly w Screen 10001751 18 Control Door Assembly 10001790 19 Catch Control Door 10001743 20 Remote Switch Kit not shown 53858 21 Remote Switch 53606 22 Remote Switch Wiring Harness 57265 2...

Страница 14: ...uds provided on base of the fireplace Tighten with nuts 4 Install thermal sensor element on screw studs located to the right of the gas valve on the burner base 5 Plug in grounded service cord to a convenient wall receptacle HS114 FK24 fan install 12 02 Stud Fan is installed at the back of the pedestal Fan Speed Control Juction Box Valve Thermal Sensor Location HS114 Fig 14 FK24 fan location Remote...

Страница 15: ...nd to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defective in material or workmanship provided...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation ...

Отзывы: