27
Oxford Direct Vent / Natural Vent Gas Heater
30005123
Fuel conversion Instructions
WARNING! This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having ju-
risdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property
damage, personal injury or loss of life. The quali-
fied service agency is responsible for the proper
installation of this kit. The installation is not proper
and complete until the operation of the converted
appliance is checked as specified in the manufac-
turer’s instructions supplied with the kit.
cAUTION: The gas supply shall be shut off prior
to disconnecting the electrical power, before pro-
ceeding with the conversion.
ST770
DW
attach gas line
5/15/03 djt
PI
LO
T
O
N
OFF
PI
LO
T
AD
J
LO
HI
Gas Supply Inlet
Main Gas
Line
ST770
Fig. 48
Attach the gas line to the left side of the valve.
conversion precautions
Before proceeding, turn control knob on valve to OFF and
turn gas supply OFF. Turn OFF any electricity that may be
going to the appliance.
conversion procedure
1. Remove stove front. Lift stove front up and then swing
bottom out and away to disengage from the stove
body. (Fig. 58, Page 30)
2. Swing open the swiveling latches at the top left and
right corners of the glass frame. (Fig. 59, Page 31)
3. Pull the top edge of the glass and frame assembly
away from the firebox face. Place the assembly out of
the way on a flat, padded surface such as a counter
protected by a towel.
4. Remove the logset from the firebox.
5. Remove the rear log bracket by unfastening the screw.
(Fig. 49)
6. Remove the right and left log bracket assembly by
unfastening the two screws which hold the burner in
place. (Fig. 49)
7. Hold the burner at the right hand side and lift to clear
the right burner leg. Then pull to the right to clear the
injectors on the left hand side.
8. Remove injector orifices from left burner leg using 1/2”
wrench. (Fig. 54)
9. Install conversion orifices. (Refer to Table 2)
SIT 820 Valve
1. Using TORX T20 bit, remove and discard the three
(3) pressure regulator mounting screws (A), pressure
regulator tower (B) and the spring and diaphragm as-
sembly (C). (Fig. 50)
2. Insure the rubber gasket (D) is properly positioned and
install the new HI/LO pressure regulator assembly to
the valve using the new screws (E) supplied with the
kit. Tighten the screws securely. (Ref. torque = 25 in/
lb) (Fig. 51)
3. Install the enclosed conversion label (F) to the valve
body where it can easily be seen. (Fig. 51)
ST350
Jefferson
air shutter adj
3/20/00 djt
Remove Screws
Rear Log Bracket
Pilot
Left & Right Log
Bracket Assembly
ST768
Fig. 49
Remove rear log bracket and left and right log bracket
assembly.
FC107
SIT820
valve conversion
10/03
A
B
C
OFFP
ILOT
O
Fig. 50
Remove mounting screws, pressure regulator tower
and spring and diaphragm assembly.
FC107