background image

3

10004894

LHEDV Series Direct Vent Insert

This gas appliance should be installed by a qualified installer in 
accordance with local building codes and with current CSA-
B149.1 Installation codes for Gas Burning Appliances and 
Equipment. FOR U.S. Installations follow local codes and/or the 
current National Fuel Gas Code ANSI Z223.1/NFPA 54.
In the Commonwealth of Massachusetts, all gas fittings and 
installation of this heater shall only be done by a licensed gas 
fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION OF YOUR 
GAS FIREPLACE PLEASE NOTE THE FOLLOWING:

1.  This appliance gives off high temperatures and should be 

located out of high traffic areas and away from furniture and 
draperies.

2.  Children and adults should be alerted to the hazards of the 

high surface temperatures of this appliance and should stay 
away to avoid burns or ignition of clothing.

3.  Children should be carefully supervised when they are in the 

same room as your appliance.

4.  Under no circumstances should this appliance be modified. 

Parts removed for servicing should be replaced prior to 
operating this appliance again.

5.  Installation and any repairs to this appliance should be car-

ried out by a qualified service person. A professional service 
person should be contacted to inspect this appliance an-
nually. Make it a practice to have all of your gas appliances 
checked annually.  More frequent cleaning may be required 
due to excess lint and dust from carpeting, bedding material, 
etc.

6.  Control compartments, burners and air passages in this ap-

pliance should be kept clean and free of dust and lint. Make 
sure that the gas valve and pilot light are turned off before 
you attempt to clean this unit.

7.  The venting system (chimney) of this appliance should be 

checked at least once a year and if needed your venting 
system should be cleaned.

8.  Keep the area around your appliance clear of combustible 

materials, gasoline and other flammable vapor and liquids. 
This appliance should not be used as a drying rack for cloth-
ing, nor should Christmas stockings or decorations be hung 
in the area of it.

9.  Under no circumstances should any solid fuels (wood, coal, 

paper or cardboard etc.) be used in this appliance.

10. Whether the zero clearance kit is installed directly on carpet-

ing, vinyl tile or any combustible material other than wood, 
this heater must be installed on a metal or wood panel 
extending the full width and depth of the heater. The insert 

can not be installed directly onto or into combustibles.

Installation & Operating Instructions

IMPORTANT:

PLEASE READ THE FOLLOWING CAREFULLY

It is normal for fireplaces fabricated of steel to give off some 
expansion  and/or  contraction  noises  during  the  start  up  or 
cool down cycle.  Similar noises are found with your furnace 
heat  exchanger or car engine.
It is not unusual for your gas fireplace to give off some odor 
the first time it is burned.  This is due to the curing of the paint 
and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open 

all windows.

It is recommended that you burn your fireplace for at least ten 
(10) hours the first time you use it.  If optional fan kit has been 
installed, place fan in the "OFF" position during this time.

Locating Your Gas Fireplace Insert 

with Zero Clearance Kit

Proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

C

D

B

E

A

F

X

X

X

FP1249a

locating DV unit

with zero clearance kit

4/03

FP1249a

Fig. 1

  Locating unit with zero clearance kit.

 

A)   Flat on wall  

B)   Cross corner

 

C)   Island 

D)   *Room divider

 

E)   *Flat on wall corner 

F)   Chase installation

NOTE: 

(Fig. 1)

*  When you install your fireplace in (D) Room divider or (E) Flat 
on  wall  corner  positions,  a  minimum  of  6  (X)  inches  (153mm) 
clearance must be maintained from the perpendicular wall and 
the outer edge of the trim.

Before installing the gas fireplace insert, consideration must 
be given to the functioning needs of the fireplace.  The size 
of the fireplace cavity (min. 25

¹⁄₄

"W x  17

¹⁄₂

"H x 13

¹⁄₂

" D (641 x 

438 x 343 mm) for the LHECDV20 and LHERDV20, 28

³⁄₄

"W 

x 21"H x 15

¹⁄₂

"D (730 x 533 x 394 mm) for LHECDV30 and 

LHERDV30), the design of the chimney for effective venting 
should be determined. The availability of the gas supply as well 
as electricity for the insert fan must be confirmed.

Your Direct Vent Insert unit is designed to be 
vented vertically with a minimum height of 
12' (4 m).

Insert Applications

This appliance may be installed in an aftermarket per-
manently located, manufactured (mobile) home, where 
not prohibited by local codes.
This appliance is only for use with the type of gas indi-
cated on the rating plate. 

WARNING: Check with your electronics manufacturer 
before installing a television or other electronic de-
vice above this fireplace.

Содержание LHECDV20

Страница 1: ...our gas supplier call the fire department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAMAGE PER SONAL INJURY OR LOSS OF LIFE PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE INSTALLER CONSUMER SAFETY INFORMATION FOR YOUR SAFETY Installation and service must be performed by a qualified installer service agency or the...

Страница 2: ...eparation 6 Gas Line Installation 6 Gas Supply Pressures 7 Fan Kit 7 Fan Removal Instructions 7 Installation of Trim Switch for RN RP Gas Valves 7 Venting and Installation 8 Liner Installation 9 Round Vent Termination Installation 11 Ceramic Refractory Installation 11 Venting Components 12 Operating Instructions General Glass Information 13 Louvre Removal 13 Glass Cleaning 13 Glass Frame Removal 1...

Страница 3: ... a metal or wood panel extending the full width and depth of the heater The insert can not be installed directly onto or into combustibles Installation Operating Instructions IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle Similar noises are found with your furna...

Страница 4: ...3 343mm 15 394 mm 16 419 mm H 17 432 mm 17 432 mm 20 521 mm 20 521 mm I 18 457 mm 18 457 mm 21 546 mm 21 546 mm J 19 486 mm 19 486 mm 22 575 mm 22 575 mm K 15 381 mm 15 381 mm 17 432 mm 18 457 mm L 10 264mm 10 273 mm 11 298 mm 12 324 mm M 8 216 mm 8 216 mm 8 216 mm 8 216 mm N 37 946mm 37 946 mm 37 946 mm 37 946 mm O 19 486 mm 19 486 mm 19 486 mm 19 486 mm P 27 692 mm 27 692 mm 27 692 mm 27 692 mm ...

Страница 5: ...eplace If the fireplace is recessed into the wall and at least 12 305 mm above floor level no hearth is required The use of wallpaper adjacent to this fire place is not recommended as high tem peratures given off by this fireplace may adversely effect the binders in the adhe sive used to apply the wallpaper NOTE Insulating around the fireplace will result in overheating and possible malfunctioning of t...

Страница 6: ... test point up stream of the control When using copper or flex connector use only approved fittings Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing See gas specifications for pressure details and ratings NOTE If flex connector is used it must be kept inside of the heater These gas inserts are approved for installation in solid fu...

Страница 7: ...al codes or in the ab sence of local codes with the current CSA C22 1 Canadian Electrical Code U S Installations follow local codes and the National Electrical Code ANSI NFPA No 70 Should this fan require servicing the power supply must be disconnected For rewiring of any replacement components refer to Figure 6 Fan Removal Instructions 1 Turn off gas and electricity 2 Remove the front glass 3 Rem...

Страница 8: ...Off switch wiring Honeywell Valve Fig 8 For left side installation reverse switch position in bracket FP1331 on off switch 4 03 FP1331 WARNING Some factory built fireplaces have air passages on face of fireplace for zero clearance capabilities Under no circumstances should these passages be blocked Venting Installation 1 The fireplace may be installed in and vented through any solid fuel fireplace tha...

Страница 9: ...p fastener plate and move it to the back first before sliding the flue collar plate out from the top of the unit Fig 13 2 Apply a bead of hi temp sealant on the end of the collar before attaching the liner to the flue collar Fasten it with two clamps then adjust fastener plate all the way to the back before sliding flue gas plate back onto the unit Figs 14 and 15 3 After the flue collar plate is set on...

Страница 10: ...e collar plate Flue Collar Plate Fastener Plate Cabinet Top 10 24 x 1 Machine Screw FP1281 Fig 13 Remove flue collar plate assembly FP1282 flue collar seal 1 03 Damper 3 Flex Vent Two Pieces Clamps Screw Fastener Plate Gasket Unit FP1282 Fig 14 Apply high temperature sealant to end of collar FP1283 unit in place 1 03 Front Frame Damper 3 Chimney Liner Two Pieces Clamps screw Flue Collar Plate Unit ...

Страница 11: ...Edge Left Side Right Side Center FP1329 Fig 19 Ceramic refractory Bottom Edge Round Vent Termination Installation Round Vent Termination Model HEDVRT is designed to be installed onto the LHECDV20 LHERDV20 LH ECDV30 and LHERDV30 direct vent insert fireplaces This round vent termination is built to be installed onto any type A vent round chimney or B vent round chim ney The minimum inside venting dia...

Страница 12: ... 12 Fit typical 12 13 x 12 13 flue tile Kit Includes A Vent Termination SL x1 B Stainless Steel Clamps 3 3 5 x4 C Hardware Package x1 D High Temperature Sealant Round Vent Termination Kit Model HEDVRT Fits typical A or B Vent with minimum 7 178 mm inside diameter and 14 357 mm maximum outside diameter Kit Includes A Round Vent Termination B Stainless Steel Clamps 3 3 4 C Hardware Package 1 D Extend...

Страница 13: ...Frame Removal LHECDV20 and LHERDV20 1 Remove two 2 screws at the bottom of the frame Fig 17 2 Lift up and unhook glass frame at the top Log Installation and Burner Lava Rock 1 Remove glass frame See Glass Removal section 2 Remove logs from packaging 3 Place logs according to the model instructions be low LHECDV20 LHERDV20 Fig 22 a Place rear left log JR7 Use the log s bottom holes to locate it ont...

Страница 14: ... Use the log s bottom holes to locate it onto the two 2 pin studs of the rear log bracket on the left c Place rear right log KR23 Use the log s bottom holes to locate it onto the two 2 pin studs of the rear log bracket on the right d Place the front left log KR25 Position the log notch against the second grate from the left and the other edge of the log on top of the rear left log notch Ensure the...

Страница 15: ...awhile This is due to paint and lubricants used in the manufacturing process After each lighting vapor may condense and fog the glass this moisture disap pears within a few minutes of burning It is important to periodically perform a visual check of the pilot and the burner flames Compare them to the Figure 26 and Figure 27 or 28 If any of the flames ap pear abnormal call a service person Flame Char...

Страница 16: ...BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s To Turn Off Gas To Heater L...

Страница 17: ...er wire accross terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connections are bad B Thermopile may not be 1 Be sure wire connections from thermopile at generating sufficient gas valve terminals are tight and thermopile is millivoltage fully inserted into pilot bracket 2 One of t...

Страница 18: ...st Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs A Minimum of 14mv Defective Valve Turn To Pilot Meter Should Read Greater Than 100 Mv If Not Replace Pilot Lights With Piezo Ignitor YES YES YES YES Pilot Stays Lit Pilot Lights Main Burner System OK START CHECK Valve Is Turned On On off Switch Is Not Turned On Watch For Grounded Wires Thermopile Needs A Minimum 325...

Страница 19: ...n control 7 If the manual switch is in the LOCAL position the valve will be at the highest fixed pressure setting The transmitter will control the fan only Shut Off Procedure If the manual switch is in the REMOTE position the transmitter can shut off the main burner and fan How ever the control is still on and a command from the transmitter can turn on the main burner or fan To shut off the system ...

Страница 20: ...AUTO mode push the time and down keys simultaneously for at least 3 seconds To Change Batteries 1 Remove cover on the backside of the transmitter Install 3 AAA batteries as shown and reattach cover 2 Once steps 1 3 in OPERATION are completed receiver valve and transmitter are now ready Press any button on transmitter for recognition process to occur between the receiver valve and transmitter 3 Use...

Страница 21: ...ode will clear itself after approximate ly 1 minutes and return to normal operation If the setting is above room temperature on the transmitter does the main valve and fan turn on If the setting is below room temperature on the transmitter does the main valve and fan turn off Turn pilotstat knob to OFF to turn valve completely off Auto Path Yes Yes No If the manual switch is set to REMOTE press th...

Страница 22: ...it period Cycle switch once and leave in remote Press any key on transmit ter for recognition operation Local Path Move switch from local to remote Press any key on transmitter Move switch back to local Yes Yes If the manual switch is set to REMOTE press the mode but ton to display ON Does transmitter con trol the main burner and fan Does transmitter change levels of flame height fan speed and set ...

Страница 23: ... an occa sional checkup and cleaning and some may require ad justment If repair is necessary it should be performed by a qualified technician In order to properly clean the burner and pilot assembly turn off the gas to the unit remove the window frame panel and logs exposing the burner and pilot assembly Clean all foreign materials from the top of the burner Check to make sure that burner parts are...

Страница 24: ...18 17 11a b 12a b 13a b 15 20 23 a b 21 22a b LOCAL REMOTE ON PILOT OFF L E D 24a b 25 26 27 28 29 30 31 32 33 35 34 36 41 40 42 43 44 45 46 47 48 49 50 4894 LHEDV parts 4 03 51 37 38 CFM Corporation reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice LHEDV Series 4894 ...

Страница 25: ...0001741 10001741 10001741 10001741 11b Pilot Assembly PSE Prop 10001742 10001742 10001742 10001742 12a Pilot Assembly RFN Nat 20002266 20002266 12b Pilot Assembly RFP Prop 20002268 20002268 13a Pilot Orifice RFN Nat 20000908 20000908 13b Pilot Orifice RFP Prop 20000907 20000907 14 Pilot Tubing w Fittings 10001296 10001296 10001296 10001296 15 Manifold Tubing w Fittings 57318 57318 57318 57318 16 The...

Страница 26: ...0005098 10005098 42 Bracket Rear Log Assembly 10005370 10005369 10006771 10005489 43 Bracket Log Support Assembly 10004885 10004885 44 Gasket Cover Gas Line Access 10004227 10004227 10004227 10004227 45 Bracket Support Grate 10003479 10003479 46 Hinge 2 Springs 52356 52356 52356 52356 47 Shield Heat Pilot 10000248 10000248 10000248 10000248 48 Plate Relief with Gasket 10002032 10002032 10002032 10...

Страница 27: ...escription LHER20CR Ceramic Fiber Brick LHEC20CR Ceramic Fiber Brick LHEC30CR Ceramic Fiber Brick LHER30CR Ceramic Fiber Brick Face Kits NOTE One is required for LHEC20 and LHEC30 Model Description LHEC20FB Louvre T B Black LHEC20LKB Filigree T B Black LHEC20LKS Filigree T B Pewter LHEC30FB Louvre T B Black LHEC30LKB Filigree T B Black LHEC30LKS Filigree T B Pewter LHEC30LKG Filigree T B Gold LHEC...

Страница 28: ...28 10004894 LHEDV Series Direct Vent Insert ...

Страница 29: ...29 10004894 LHEDV Series Direct Vent Insert ...

Страница 30: ...30 10004894 LHEDV Series Direct Vent Insert ...

Страница 31: ...s shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defective in m...

Страница 32: ...HECDV20RFN 61 3 69 72 65 LHECDV30RFP 61 3 70 73 65 LHERDV20RN 59 7 69 N A 64 LHERDV20RP 59 7 70 N A 64 LHECDV30RN 61 5 70 73 66 LHECDV30RP 61 5 71 74 66 LHECDV30RFN 61 5 70 73 66 LHECDV30RFP 61 5 71 74 66 LHERDV30RN 64 1 69 N A 65 LHERDV30RP 64 1 70 N A 65 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation ...