51D0528
37
LX Series Direct Vent Gas Fireplace
•
Never operate fireplace if glass is broken.
•
Replace any glass that is chipped, cracked, or broken.
Replacement glass assemblies MUST be supplied by
fireplace manufacturer —
No substitute materials may
be used.
cLeANING
and
MAINteNANce
c
A
ut
Io
N
Always use gloves when handling broken
glass.
W
ARNING
Make sure the glass panel edges do not
touch any metal parts during thermal
expansion.
FP2722
Lx blower
LX32
LX36
BLoWeR
FP2722
White
(Hi Temp)
OFF
Variable
Fan Control
ON
White
(Hi Temp)
Fan Limit
Switch
(N.O.)
White
(Hi Temp)
Blower
Motor
Black
White
Green
110/115 V.A.C
Blower Plug
FP2723
blower wiring
White
(Hi Temp)
OFF
Commande
de ventilateur
variable
ON
Blanc
(Hi Temp)
limite de
commatateur
de ventilateur
(N.O.)
blanc
(Hi Temp)
Moteur de
ventilateur
Noir
Blanc
Vert
Pise ventilateur
110/115 v. ca
WIRING DIAGRAM FoR BLoWeR