Страница 1: ...ANCE IS NOT PROPERLY INSTALLED OPERATED AND MAIN TAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA 8662 EWF30 cover 3 05 ...
Страница 2: ...specifications please refer to Page 4 The EWF30 is designed tested and listed for burning wood Do not burn other fuels We recommend that you hire a professional installer certified by Wood Energy Technical Training WETT to install your EWF30 or to advise you on the installation should you attempt to install it yourself Please read the appropriate sections of this manual before you install and use yo...
Страница 3: ...ns Installation other than as instructed by CFM Corporation or Installation and or use of any component part not manufactured or approved by CFM Corpo ration in combination or assembly with a CFM Corporation fireplace system notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory Any such action may possibly cause a fire hazard Consult lo...
Страница 4: ...nonstandard construction e g unusually well insulated not insulated built under ground etc or if you live in a more severe or more temperate climate these figures may not apply Since so many variables affect performance consult your Ver mont Castings Authorized Dealer to determine realistic expectations for your home EWF30 EWF30 Woodburning Fireplace Fig 1 EWF30 specifications and framing 12 305 mm ...
Страница 5: ...n Insulation methods shown are optional for cold climate not a requirement for unit operation Termination Cap Storm Collar Pan Flashing Draftstop Batt Insulation cut out around firestop Firestop Ceiling Level Standoff Metal Safety Strips 1 2 or 3 pieces Batt Insulation MUST be used in the Chase Electrical Access Andiron Brick Ledge ...
Страница 6: ...angled run of chimney Chimney supports are required for every 30 feet and 60 feet SK8 pipe or 20 feet and 40 feet 3 wall pipe of ver tical chimney height above the hearth Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling NOTE This offset distance may not be your full offset dis...
Страница 7: ... chimney to the peak of the roof is more than 10 3m a chimney height reference point is established that is on the surface of the roof a distance of 10 3m from the chimney in a horizontal plane The top of the chimney must be at least 2 610mm above the reference point but never less than 3 914mm in height above the high est point where it passes through the roof 2 Min 2 Min 3 Min 0 To 10 3 Min 0 To...
Страница 8: ...ler for assistance Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible Insulate base of fireplace with a noncombustible insulation rated for a minimum of 300 F Insulating is very important for outside wall installations over a concrete slab ...
Страница 9: ...ed in shipment specifically check the end connection of chimney sections and elbows NOTE Fireplaces may use CFM Corporation Model SK8 or Model S three wall chimney systems The BR BC Series Fireplace will accept the SK8 chimney system as is but a TWABR adapter collar is required when using the Model S triple wall chimney system The installation procedure described in this manual applies only to the ...
Страница 10: ...the framed ceiling hole Positioning Safety Strips Securing the Fireplace Slide fireplace into position Safety strips are used to ensure that any combustible materials in front of the fireplace are protected even though a noncombustible hearth extension is required When the finished extended hearth is added the top of the finished hearth must be flush with the bottom of the fireplace Z shaped metal safet...
Страница 11: ...AUTION Do not install termination into a garage or other area that could contain flammable liquids or fumes or into an attic space Installation Instructions Determine the location of the fireplace as described in the fireplace Installation Manual Then plan location of the duct termination and the route of the duct run between the fireplace and the duct termination Duct run must be limited to a maximum...
Страница 12: ...mination Rain Cap FP1061 Fig 15 Caulk and install duct termination rain cap in place UP FP1566 EWF Pipe install Circulating models 3 05 djt Pipe Section Pipe Rim Hem Lance Pipe Hem FP1566 Fig 16 Install pipe listening for the snap lock to fasten P1592 utside air cover 0 05 Outside Air Opening Air Inlet Opening FP1592 Fig 14 Use outside air cover plate to cover air inlet opening 2 Attach the inlet ...
Страница 13: ...pacer Joist Firestop Spacer Nails 4 Ceiling Installation FP593 Fig 17 Firestop spacer installations Canadian Requirements for Insulation Shield In Canada an attic insulation shield is required to pre vent attic insulaiton from contacxting the chimney sec tion Framing dimensions for the chimney hole should measure 14 x 14 368 x 368 mm An attic shield MUST be installed on top of attic joists above t...
Страница 14: ...ns Since you have already preplanned the height of your termination according to the Ten Foot Rule continue to install pipe to the predetermined height Check the chimney top installation instructions for details on how high above the roof top the chimney sec tions all pipes should extend Install Top Housing or Termination Follow the installation instructions provided with the chimney termination y...
Страница 15: ...tible Finish Mate rial Only in this Area Top View Mantels The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel This also applies to the distance between the mantel leg if fitted and the fireplace For the correct mounting heights and widths refer to Figures 22 and 23 When using paint or lacquer to finish the mantel such paint or lacquer must be heat ...
Страница 16: ... 26 WARNING Hearth extension must be installed in accordance with Figure 25 Top of hearth extension must be level with bottom of fireplace Alternate noncombustible materials may be used providing the total thermal resistance Rt value of the alternate material employed is greater than or equal to R 1 09 Thermal resistance R or thermal conductivity K may be obtained from manufacturer of the material ...
Страница 17: ...nce to combustible perpendicular wall B Min clearance to combustible perpendicular wall when using noncombustible wall shield Side Wall Side Wall F C E E D 4 Brick Example material Combustible material permitted within shaded area Noncombustible wall shield requires 1 EH2416 insulation minimum R Value 1 85 between decorative noncombustible rigid covering and combustible wall Minimum height and wid...
Страница 18: ...wn FP1569 EWF30 FP1569 Screw Wood Shaft Metal Hub The primary air control is located in the upper left corner of the unit Fig 27 It is the primary source of air for starting maintaining and reviving the fire Generally more air entering the fireplace makes the fire burn hotter and faster while less air prolongs the burn The air supply is open to the maximum when the control lever is pushed down and cl...
Страница 19: ...Air Control Settings that Work Best for You No single air control setting will fit every situation Each installation will differ depending on the quality of the fuel the amount of heat desired and how long you wish the fire to burn The control setting also depends on your particular installation s draft or the force that moves air from the fireplace up through the chimney Draft is affected by such th...
Страница 20: ... drawing and repeat the procedure as often as necessary if the initial attempt is unsuccessful 5 Once a good ember bed of at least 2 3 51 76 mm has formed let the fire burn hot for an additional ten to fifteen minutes 6 Close the damper and the primary air control to a medium low setting as described on Page 18 The fire volume will diminish immediately but the fire place will continue to heat up Maint...
Страница 21: ...treme care Hold the ash pan with both hands to avoid dropping or spilling the ashes Take the pans outdoors and empty the ash into an ash container Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pans and front door Empty the ash pans regularly typically every one to three days The frequency will vary depending on how you operate y...
Страница 22: ... screw one turn by turning it with an Allen wrench 3 Retighten the lock nut while at the same time hold ing the striker screw with the Allen wrench to prevent its turning Test the door seal Close the door on a dollar bill and attempt to pull it free If the bill is freed with little resis Maintenance ST531 Door Pawl 11 00 Pawl Small Lock ing Nut Large Locking Nut Set Screw Striker Screw Handle Stub...
Страница 23: ...the chimney and chimney connector Learn to Recognize and Avoid Creosote The EWF30 has been designed to reduce creosote build up significantly However regular chimney in spection and maintenance must still be performed For safety good fireplace performance and to protect your chimney and chimney connector inspect your chimney and chimney connector on a regular schedule Clean the system if necessary F...
Страница 24: ...cleaning the chimney reinstall the chimney cap according to the manufacturer s directions Maintenance Schedule Fireplace Daily Ash should be removed before the level reaches the top of the pan Check each time you re load or at least once a day Keep the area around the fireplace clear of any com bustible material Yearly Spring Cleaning Remove ash from the fire box and replace with a moisture absorbin...
Страница 25: ...y cap used to terminate chimney SLTSK8 through a chase Terra Cotta Masonry Includes adapter Flashing not included SK8 Chimney Sections Pipe used to build 8 SK8 flue systems SK81 1 Long SK818 1 Long SK83 3 Long SK84 4 Long SK8 Chimney Elbows Elbow used to create an offset in an 8 SK830 2 chimney system Only 30 elbows available Packaged 2 per carton offset and return Firestop Required at each floor le...
Страница 26: ...21 16 3 2 1 11 12 32 33 28 20 19 20 19 8 17 5 8662 EWF30 parts 5 05 24 22 52 Ref Description EWF30 1 Deflector Cabinet Top 54518 2 Louvre Assy Bottom 10000038 3 Louvre Assy Top 10000037 4 Damper Air Wash Assy 20008641 5 Ashpan 30002240 6 Brick Ash Lip 20008714 7 Andirons 20006298 8 Firebrick Insulation 20008736 9 Glass 20008684 10 Gasket 1 4 3ND Black 1203560 11 Front Handle w Shaft 1 8 Nickel Hori...
Страница 27: ...y NI 5004264 30 Rd Hd Sl 8 32x2 Z Screw 1201243 31 Knob Therm Handle Maple Wood Blk 1600660 32 Black Fall Away Handle 20006382 33 Handle Ceramic Black 20006381 34 Top Cast Plate 20008617 35 Damper 20005982 36 Tab Damper 1601488 37 Damper Rod Clamp 20005985 38 Damper Rod 20005984 39 Damper Clamp 20005990 40 CS Hex hd 1 4 20 x 5 8 Blk 1201372 41 3 8 Flat Washer SS 20006839 42 CS Hex Hd 3 8 16 x 1 Fu...
Страница 28: ...onnected when the unit was installed the fan lead can be directly plugged into the EB 1 plug socket The fireplace when installed must be electrically connected and grounded in ac cordance with local codes with the current CSA C22 1 Canadian Electrical Code or for US installations follow local codes and the National Electrical Code ANSI NFPA No 70 Any electrical rewiring of this fan must be complete...
Страница 29: ...rick ledge for masonry applications if needed are available to enhance the look of your EWF30 fireplace Installa tion instructions are included with the kit Model Description EWF30SFP Steel Face Plate EWF30SFD Decorative Steel Face Plate FP1579 EWF30SFP EWF30SFD Fig 33 Decorative steel face plates ...
Страница 30: ...30 Vermont Castings EWF30 20008662 ...
Страница 31: ...aused by burning salt saturated wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a fireplace repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to the unit while in transit is not covered by this warranty but is subject to a claim against the common carrier Contact Vermont Castings Authorized Dealer from whom you p...
Страница 32: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation ...