Vermont Castings Dutchwest 2478 Скачать руководство пользователя страница 5

5

Dutchwest Non-Catalytic Convection Heater

30002278

Prefabricated Chimneys

A prefabricated metal chimney must be one tested and 
listed for use with solid-fuel burning appliances.  
A horizontal connector run should be inclined 1/4” per 
foot (20 mm per meter)  from the stove toward the 
chimney.  The recommended maximum length of a hori-
zontal run is 3 feet (1m) and the total length of chimney 
connector should be no longer than 8 feet (2.5m).

Chimney Height

For proper draft and good performance, the chimney 
should extend at least 16’ (5 m) above the flue collar of 
the stove.
The chimney must also extend at least 3’ (914 mm) 
above the highest point where it passes through a roof, 
and at least 2’ (610 mm) higher than any portion of a 
building within 10’ (3 m). (Fig. 2)

DO NOT CONNECT THIS UNIT TO A CHIMNEY 
FLUE SERVING ANOTHER APPLIANCE. 

Chimney Size

The Model 2478 heater should be vented into a ma-
sonry chimney with a square flue with nominal flue size 
of 8” x 8” (203 x 203 mm), or a round flue with nominal 
flue size of 6” (152 mm). 
Chimney liners larger than 8” x 12” (203 x 305 mm) 
may promote rapid cooling of smoke and reduction in 
draft, especially if they are located outside the home.  
These large chimneys may need to be insulated or 
have their flues relined for proper stove performance.  
Accessories to help make the connection between 
stainless steel chimney liners and the stove are avail-
able through your local dealer.

2' Min.

2' Min.

3'

Min.

0 To 10'

3'

Min.

0 To 10'

AC246

4/1/96

Reference

Point

AC246

Fig. 3

  The 2/3/10 rule for chimneys.

Guidelines for Installing 

the Chimney Connector

The chimney connector is the single-wall pipe, or listed 
and approved double-wall pipe that connects the stove 
to the chimney.  The chimney itself is a masonry or 
prefabricated structure that encloses the flue.  Chimney 
connectors are used only to make the connection from 
the stove to the chimney.
Do not pass the chimney connector through a combus-
tible wall, floor, or ceiling, through an attic or roof space, 
or through a closet or similar concealed space.  If pas-
sage through a combustible wall is unavoidable, follow 
the recommendations in the following section on Wall 
Pass-Throughs.  Keep the passage as short and direct 
as possible, with no more than two 90 degree turns.  

Two Types of Connector

You may use either a single-wall steel connector of the 
size and gauge described below, or a listed and ap-
proved double-wall connector.

Single-Wall Connector

The single-wall chimney connector should be made of 
24 gauge or heavier steel, and must have a minimum 
internal diameter of  6” (150 mm) for model 2478.
Install single-wall chimney connector not less than 18” 
(450 mm) from the ceiling.
In cathedral ceiling installations, extend the prefabri-
cated chimney downward to within 8 feet (2.5 meters) 
of the stove.  The entire chimney connector should be 
exposed and accessible for inspection and cleaning.
Do not use galvanized chimney connector; it cannot 
withstand the high temperatures that can be reached 
by smoke and exhaust gases and it may release toxic 
fumes under high heat.

ST418

chimney connector

6/00

Chimney

Elbow

Slip Pipe

Standard Connector

Flue Liner

Flue

Thimble

Flue Collar

Floor Protector

ST418

Fig. 4

  Sections of a steel chimney connector of at least 24 

gauge thickness are fastened together with screws to 
connect the stove to the chimney.

Содержание Dutchwest 2478

Страница 1: ...erating Manual If this heater is not properly installed operated and maintained a house re may result For safety follow all installation operation and maintenance directions Contact local building of...

Страница 2: ...to cause cancer birth de fects and other reproductive harm California Health Safety Code Sec 25249 6 Table of Contents Speci cations 3 Installation 4 Clearances 10 Assembly 16 Operation 18 Maintenanc...

Страница 3: ...in a more severe or more temper ate climate these gures may not apply Since so many variables affect performance consult your Dutchwest Authorized Dealer to determine realistic expectations for your...

Страница 4: ...ed to 1 a chimney complying with the requirements for Type HT chimneys in the standard for Chimneys Fac tory Built Residential Type and Building Heating Appli ance UL 103 or 2 a code approved masonry...

Страница 5: ...nector The chimney connector is the single wall pipe or listed and approved double wall pipe that connects the stove to the chimney The chimney itself is a masonry or prefabricated structure that encl...

Страница 6: ...elescoping joints with at least three sheet metal screws 3 Secure the chimney connector to the chimney In structions for various installations follow below 4 Con rm that the installed stove and chimne...

Страница 7: ...back into the replace chimney The liner of the replace chimney should extend at least to the point at which the chimney connector enters the chimney Follow all the guidelines for installing a chimney...

Страница 8: ...gle wall connector to provide the required 12 305 mm clearance for the connector Any material used to close up the opening must be non combustible The following wall pass through methods may be ap pro...

Страница 9: ...t 0 744 Refer to How to Deter mine if Alternate Floor Protection Materials are Accept able section The oor protector may be covered with a decorative noncombustible material if desired Do not obstruct...

Страница 10: ...installations must include the bottom heat shield The oor protector must also meet standard requirements for freestanding installations Floor Protection for Fireplace Installations with Standard Legs...

Страница 11: ...ombustible surface Keep furnish ings and other combustible materials away from the stove as well In general a distance of 48 1220 mm must be maintained between the stove and moveable combustible items...

Страница 12: ...himney Connector Clearance Chart that follows For example the letter A gives the minimum side clear ance for installations in which the stove is not equipped with any heat shield and the wall beside t...

Страница 13: ...7 heat shield 432 mm 381 mm 191 mm 178 mm 368 mm 178 mm Double wall connector Chimney Connector Clearance Single wall connector 20 14 No connector heat shield 508 mm 356 mm Single wall2 connector 10 6...

Страница 14: ...dutchwest flue centerline 6 30 00 djt A B C E D F C F Chimney Connector Side Rear Corner Side Rear Corner Listed Approved A 30 B 13 C 18 D 21 E 12 F 18 Double wall with 762 mm 330 mm 470 mm 533 mm 318...

Страница 15: ...1220 mm 60 1525 mm Spaced 1 25 mm from Floor ST802 Fig 17 Sidewall protection ST803 corner wall protection 5 04 60 1525 mm 48 1220 mm Spaced 1 25 mm from Floor ST803 Fig 18 Corner wall protection Wall...

Страница 16: ...ottom Heat Shield is required in many instal lations Refer to the oor protection information found in the Installation Section of this manual Attach the Legs and Heat Shield NOTE To avoid damaging the...

Страница 17: ...ssen the effort of moving the stove over smooth ooring is to slide it on a piece of inverted carpet Move it slowly to ensure the oor is not scratched Retighten all leg fastening hardware ST815 back le...

Страница 18: ...Opening the inlet shutters provides air for primary combustion To open the shutters turn the lever clockwise The shutters are all the way open when the lever points to ward the rear at a 9 00 positio...

Страница 19: ...ulting in short burn time and dimin ished stove performance If you must burn it mix it in with greener wood to slow the burn Store your rewood under cover to keep it dry Even for short term storage ke...

Страница 20: ...ase the ring rate of your heater by altering the air control adjustment range outlined in these directions In some newer homes that are well insulated and weather tight poor draft may result from insu...

Страница 21: ...RT THE FIRE DO NOT BURN GARBAGE OR FLAM MABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Also never use gasoline type lantern fuel kerosene charcoal lighter uid or similar liquids to start or freshe...

Страница 22: ...ace in a metal container with a tight tting lid ST438 ash pail 7 6 00 djt ST438 ST805 remove ashes 5 04 ST805 Fig 28 Check the ash compartment before reloading the stove Safe Ash Handling Ashes may co...

Страница 23: ...sen the small locking nut with an open end wrench 2 Use the allen wrench included with the stove to turn the striker screw clockwise one quarter turn and close the door to test the engagement The door...

Страница 24: ...o 2 nuts on the threaded rods that secure the top plate to the inner top of the stove 2 Remove the top plate and open the damper 3 Loosen the adjusting bolt s lock nut Fig 32 4 Loosen the anchor bolt...

Страница 25: ...ve cool completely before you inspect the chimney Use a ash light and mirror to sight up the ue through the chimney clean out door or chimney connector inspection tee If no inspection access is availa...

Страница 26: ...or and the elbows Clean the system if nec essary ANNUAL SPRING CLEANING Disassemble the chimney connector and take it outdoors for inspection and cleaning Replace weak sections of connector Inspect th...

Страница 27: ...ure from the high ue temperatures Because the insulation is less dense than masonry the inner steel liner warms up more quickly than a masonry chimney this makes the steel chimney support a good draft...

Страница 28: ...y re All of the installation characteristics that adversely affect chimney draft also promote creosote condensation Consequently you can minimize creosote accumulation with an effective chim ney desig...

Страница 29: ...Conclusion Woodburning is more an art than a science Art in cludes technique and since installations homes and fuel vary the stove operator must also vary technique mostly timing to achieve satisfyin...

Страница 30: ...Convection Heater Model 2478 29 26 27 32 37 21 19 12 38 41 24 25 16 30 37 23 42 39 35 1 14 13 4 43 2 6 9 10 17 11 7 3 34 20 22 18 33 44 45 46 8 47 40 36 47 41 31 28 15 Ref Description 2478 1 Bottom 3...

Страница 31: ...oor Gasket Front Ash and Load Doors 1203589 26 Load Door Insulation 30002210 27 Load Door Refractory to June 2005 30002214 Load Door Refractory II replaces above 30002437 28 Ceramic Handle w Lifter Wo...

Страница 32: ...e to the stove caused by burning salt saturated wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Dut...

Отзывы: