background image

27

Dutchwest Natural Vent Gas Heater

30002008

BASIC WARRANTY

 

CFM Corporation Company (hereinafter referred to collectively as the 
Company) warrants that your new Dutchwest Gas Fireplace/Stove is 
free from manufacturing and material defects for a period of one year 
from  the  date  of  purchase,  subject  to  the  following  conditions  and 
limitations.

EXTENDED LIFETIME WARRANTY

 

The heat exchanger, where applicable, and combustion chamber of 
every Dutchwest gas product is warranted for life against through wall 
perforation.  All  appliances  equipped  with  an  Insta-Flame  Ceramic 
Burner have limited lifetime coverage on the ceramic burner plaque. 
Warrantees are made to the original owner subject to proof of purchase 
and the conditions and limitations listed on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

 

Note

: On porcelain enamel finished external parts and accessories The 

Company offers no Warranty on chipping of enamel surfaces. Inspect 
all product prior to accepting it for any damage to the enamel.

 

 The salt air environment of coastal areas or a high humidity environment 
can be corrosive to the porcelain enamel finish. These conditions can 
cause rusting of the cast iron beneath the porcelain enamel finish, 
which will cause the finish to flake off.

 

Dye lot variations with replacement parts and/or accessories can occur 
and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only.

 

Brass cleaners cannot be used.  Mortar 

mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC  AND  MECHANICAL  COMPONENTS:  Electronic  and 
mechanical components of the burner assembly are covered for one year. 
All steel tube burners are warranted for one year.
ACCESSORIES:  Unless  otherwise  noted  all  components  and  CFM 
Corporation company supplied accessories are covered for a period of 
one year.

CONDITIONS AND LIMITATIONS

•  This  new  Dutchwest  product  must  be  installed  by  a  competent, 

authorized, service contractor. A licensed technician, as prescribed 
by  the  local  jurisdiction  must  perform  any  installation/service  work. 
It must be installed and operated at all times in accordance with the 
Installation and Operating instructions furnished with the product. Any 
alteration, willful abuse, accident, or misuse of the product shall nullify 
this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel fees 

or service charges for in-home repair work. It is the dealers option 
whether the repair work will be done in the customer’s home or in the 
dealer’s shop.

•  If upon inspection, the damage is found to be the fault of the manufacturer, 

repairs will be authorized at no charge to the customer parts and/or 
labor.  

•  Any  part  and/or  component  replaced  under  the  provisions  of  this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) found 

to be defective in material or workmanship, provided that such part(s) 
have been subjected to normal conditions of use and service, after 
said defect is confirmed by the Company’s inspection.

•  The  company  may,  at  its  discretion,  fully  discharge  all  obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses  arising  from  defective  part(s),  repair,  replacement, 
or otherwise of same, will not be covered by this warranty, nor shall 
the Company assume responsibility for same. Further, the Company 
will not be responsible for any incidental, indirect, or consequential 
damages except as provided by law.

• 

SOME  STATES  DO  NOT  ALLOW  FOR  THE  EXCLUSION  OR 
LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES 
OR  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR 
CIRCUMSTANCES.    THIS  WARRANTY  GIVES  YOU  SPECIFIC 
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The  Company  neither  assumes,  nor  authorizes  any  third  party  to 

assume on its behalf, any other liabilities with respect to the sale of 
this CFM Corporation product

•  The  warranties  as  outlined  within  this  document  do  not  apply  to 

chimney components or other non CFM Corporation accessories used 
in conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is  subject  to  claim  against  the  common  carrier.  Contact  the  dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with the 
carrier).

•  The Company will not be responsible for:

a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

b)  Inadequate  ventilation  or  negative  air  pressure  caused  by 

mechanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:

a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

b)  The fireplace has been subjected to prolonged periods of dampness 

or condensation

c)  Any damages to the fireplace, combustion chamber, heat exchanger 

or other components due to water, or weather damage, which is the 
result of but not limited to, improper chimney/venting installation.

d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1)  Contact  your  supplier.    Make  sure  you  have  your  warranty, 

your sales receipt, and the model/serial number of your  CFM 
Corporation product.

2)  DO  NOT  ATTEMPT  TO  DO  ANY  SERVICE  WORK 

YOURSELF.

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY

All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner.

Содержание Dutchwest 2467

Страница 1: ...om your neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department DO NOT STORE OR USE GASO LINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE...

Страница 2: ...rements 6 Vent Layout and Height Requirements 6 Passing Through a Combustible Wall or Ceiling 7 Venting Requirements 7 Install the Optional Fan 8 Venting System Assembly 9 Connect the Gas Supply Line...

Страница 3: ...venting system WARNING Operation of this heater when not con nected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxid...

Страница 4: ...lve Inlet C L Valve Inlet 2008 Dutchwest NV dimensions 6 23 03 17 419 mm 23 584 mm 28 721 mm 4 111 mm 6 172 mm 12 318 mm 24 622 mm See Page 5 for Flue Collar Centerline Dimensions Fig 1 Dutchwest dime...

Страница 5: ...m clearance to combustible materials Maintain a 6 152 mm clearance when using single wall pipe The gas appliance and vent system must be vented directly to the outside of the building and never be att...

Страница 6: ...at a Type B vent system rising on the outside of the home be enclosed in a chase Check your local codes for requirements The minimum vent system height for the Dutchwest Natural Vent Stove is 8 2 43 m...

Страница 7: ...o 36 feet 12m in height Up to an 18 ft horizontal vent run can be installed within the vent system using a maximum of two 90 degree elbows or four 45 degree elbows B Vertical installations up to 36 fe...

Страница 8: ...snapstat bracket Use needle nose pliers to remove the black plastic grommet from the bracket Discard the bracket Connect the two wires to the two snapstat extension leads pro vided with the parts bag...

Страница 9: ...e rebox Use a B vent adapter from the same maker as the rest of the B vent components to join the rst section of venting to the draft hood The stove includes a spill switch Operating this stove when n...

Страница 10: ...f 10 0 and a mini mum inlet supply pressure of 11 0 w c In the U S Gas connection should be made in ac cordance with current National Fuel Gas Code ANSI Z223 1 NFPA 54 Since some municipalities have a...

Страница 11: ...ig 19 Attach switch assembly to rear shroud PILOT ADJ TP TH TPTH ST228 attach switch wires to valve 12 99 ST228 Fig 20 Attach switch wires to valve Install the Log Set 1 Remove the logs from their pac...

Страница 12: ...engage with the corresponding ribs at the bottom When properly installed the bottom of the stove front cannot be pulled away from the sides without also lifting it ST773 handle assy 6 6 03 3 8 Lock in...

Страница 13: ...iate the condition Pilot and Burner Inspection Each time you light your heater check that the pilot ame and burner ame patterns are as shown in Fig ures 26 and 27 If ame patterns are incorrect turn th...

Страница 14: ...ING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replac...

Страница 15: ...burner lights wires are faulty or connections are bad B Thermopile may not gen 1 Be sure wire connecitons from thermopile at gas ate suf cient voltage valve terminals are tight and thermopile is full...

Страница 16: ...il the operation of the converted appliance is checked as speci ed in the manufacturer s instructions supplied with the kit CAUTION The gas supply shall be shut off prior to disconnecting the electric...

Страница 17: ...l s Starting at 5251 ST718 Fig 33 Natural gas air shutter setting ST726 SNV air shutter lp gas position 8 23 02 djt 1 8 3 8 Air Shutter LP Position Air Shutter LP Position Con guration for Stove with...

Страница 18: ...Rear Part Minimum Maximum Setting 000 5022 69 029 30000513 54 055 20000130 21 500 28 000 3 8 Open Conversion to Natural Gas Input BTU h Air Shutter Kit Front Part Rear Part Minimum Maximum Setting 00...

Страница 19: ...ture stove paints available through your local dealer to touch up areas as needed Clean areas to be painted with a wire brush and be sure to cover the logs burner and valve assembly glass and frame as...

Страница 20: ...upply before inspecting the system Both the inner exhaust pipe and the outer combustion supply pipe must be checked to con rm that they are unblocked and in good condition Check the Gas Flame Regularl...

Страница 21: ...Rheostat Chassis Ground RHEOSTAT SNAPSTAT BOX Snapstat BLK B L K BLK BLK BLK WHT ST153 rdv connections diag 10 99 Fig 42 Fan circuit MOTOR SNAPSTAT ON OFF RHEOSTAT WHT WHT BLK BLK BLK GRN BLK ST236 F...

Страница 22: ...s 30002005 4 Grille NV DW Gas 30002044 5 Front DW Gas 30001928 6 Door DW Gas 30001929 7 Leg DW Gas 30001930 1a 1b 1c PILO T ON OFF PILOT ADJ L O H I 15a b 16 17 18 21 20 28 25 26 27 30a b 23a b 31 32...

Страница 23: ...6 22a Ori ce Hood 69 0 0292 Front LP 30000513 22b Ori ce Hood 54 Front Natural 20000130 22c Or ce Hood 54 Rear LP 20000130 22d Or ce Hood 44 Rear NG 30000334 23a Ori ce Pilot 62 NG Top Convertible 100...

Страница 24: ...rolled by a snapstat that turns power on and off as the rebox tem perature rises above and falls below a preset tempera ture A rheostat provides for variable fan speeds Speci cations 115 Volt 60Hz 75...

Страница 25: ...25 Dutchwest Natural Vent Gas Heater 30002008...

Страница 26: ...26 Dutchwest Natural Vent Gas Heater 30002008...

Страница 27: ...stomer s home or in the dealer s shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or componen...

Страница 28: ...Ef ciency Ratings Model EnerGuide Ratings Fireplace Ef ciency 2467 51 4 2468 51 4 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: