Operating Instructions for
The Vermont Bun Baker
Chimney
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
This room heater must be connected to a 6” factory built UL 103 HT chimney (ULC S629, in
Canada) or a code-approved masonry chimney with a flue liner.
Factory Built Chimney
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be
followed. You must also purchase (from the same manufacturer) and install the ceiling support
package or wall pass-through and “T” section package, fire stops (where needed), insulation
shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended
by the manufacturer. The chimney must be the required height above the roof or other obstructions
for safety and proper draft operation. See page 8 for chimney termination requirements.