Operating Instructions for
The Vermont Bun Baker
Installation Clearances
It is extremely important that you respect required installation distances and that you respect local
installation regulations. This is for your safety! The manufacturer is not responsible for the
product, if it is not installed following these recommendations. These clearances may only be
reduced by means approved by the regulatory authority.
A combustible surface is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics etc.)
These surfaces are not limited to those that are visible and also include materials that are behind
non-combustible materials. If you are not sure of the combustible nature of a material, consult your
local fire officials.
Single wall
connector pipe
Double wall
connector pipe
A – Chimney Connector to
backwall
16.5” (419 mm)
10.5” (267 mm)
B – Chimney Connector to
sidewall
22” (559 mm)
18” (457 mm)
C – Chimney Connector to
cornerwall
20” (508 mm)
15” (381 mm)
D – Unit to backwall
14” (356 mm)
8” (203 mm)
E – Unit to sidewall
14” (356 mm)
10” (254 mm)
F – Unit to cornerwall
11.5” (292 mm)
6.5” (165 mm)