240 Volt Wall Switch Wiring Installation

A qualified electrician must perform any 

electrical wiring of this appliance. For 

Canadian installation, wiring must be done 

in accordance with local codes, and/or 

the current CSA C22.1 Canadian Electrical 

Code.  For U.S.A. installation, wiring must 

be done in accordance with the National 

Electrical Code ANSI/NFPA No. 70. 

NOTE:  For 240 Volt installations, use a double-pole, 

single-throw, 20 Amp, 240V rated wall switch.
Wiring of the wall switch must be completed prior 

to installing the unit.

Connect the wall-mounted switch to the fireplace by 

running grounded 3-conductor wire (

MIN

.

 14 AWG) to 

the switch from the junction box on the side of the unit.
1.  Locate the voltage selection switch under the logset 

on the left front corner of the unit.

2.  Move the switch from the 120 Volt to the 240 Volt 

position.

3.  Loosen the screws securing the junction box cover, 

and remove the cover.

4.  Remove knockouts in the box cover to use a cable 

clamp.

5.  Pull out three (3) wires:  black, red, and white.
6.  Connect one (1) wire (black) from the wall switch to 

the L1 (black) wire on the unit, and the other wire 
from the wall switch to the L1 (black) wire on the 
power supply. 

7.  Connect one (1) of the wires from the wall switch to 

the L2 (red) wire on the unit, and the other wire from 
the wall switch to the L2 (red) wire on the power sup-
ply. 

8.  Connect the white wire from the unit to the neutral 

(white) wire on the power supply.

9.  Connect the ground wire from the wall switch to the 

wire grouping from the power supply and ground 
stud in the junction box.

10. Ensure all connections are tight. Insert all wiring 

inside the junction box and secure the cover.

7.  Connect the white wire from the unit to the neutral 

(white) wire on the power supply.

8.  Connect the ground wire from the wall switch to the 

wire grouping from the power supply and the ground 
stud in the junction box.

9.  Make sure the red wire (L2) in the junction box has a 

closed end splice or a wire nut properly applied.

10.Ensure all connections are tight. Insert all wiring 

inside the junction box and secure the cover.

120/240 Volt Wall-Mounted  

Thermostat Wiring

Before attempting maintenance or ser-

vice—to reduce risk of fire, electrical 

shock and personal injury—disconnect all 

power to the fireplace at the main service 

panel.

NOTE:  Wiring of the wall thermostat must be com-

pleted prior to the installation of the unit.
Use a single pole thermostat rated for 120/240 Volt 

operation.
 When installing the wall thermostat, make sure to 

turn the heater control inside fireplace all the way 

clockwise to the highest set point temperature.

Connect the wall-mounted thermostat to the fireplace 

by running a grounded 2-conductor wire (min. 14 AWG) 

to the thermostat from the junction box on the side of 

the unit.
1.  Loosen the screws securing the junction box cover 

and remove the cover. 

2.  Remove knockouts in the box cover to use a cable 

clamp.

3.  Pull out the two (2) brown wires with the closed end 

splice at the end.

4.  Cut off the closed end splice, separate the two wires, 

and strip approximately 5/8" (15mm).

5.  Connect one (1) wire from the thermostat to one (1) 

of the brown wires; connect the other wire from the 
thermostat to the other brown wire.

6.  Connect the ground wire from the wall thermostat to 

the power supply wire group and the ground stud in 
the junction box.

7.  Ensure all connections are tight. Insert all wiring into 

the junction box and secure the cover.

Installation Cautions

Make sure the power is turned OFF before 

proceeding.
If repairing or replacing any electrical com-

ponent or wiring, the original wire routing, 

color coding and securing locations must 

be followed.
Any electrical repairs or rewiring of this 

unit should be carried out by a licensed 

electrician in accordance with national and 

local codes.

Содержание BREF30, BREF36, BREF42, BREF30NH, BREF36NH, BREF42NH, BREF36R, BREF42R

Страница 1: ...NG IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY SERVICE MUST BE PERFORMED BY...

Страница 2: ...20 Volt Unit Installation 8 120 Volt NH Unit Installation 8 240 Volt Unit Installation 8 Resetting the Temperature Cutout Switch 8 Screen Kit Installation 9 Service Instructions Maintenance of Motor 9...

Страница 3: ...or sparking parts inside Do not use it in areas where gasoline paint or ammable liquids are used or stored This replace should not be used as a drying rack for clothing nor should Christmas stockings...

Страница 4: ...89 mm 41 1041mm 46 1191mm L 14 356 mm 14 356mm 16 406mm M 37 953 mm 37 953mm 49 1245mm N 54 1372 mm 54 1372mm 69 1765mm O 27 686 mm 27 686mm 35 895mm N 5 8 16mm Recessed Nailing Flange G H Rough Openi...

Страница 5: ...leg minimum installation Mantel Mantel Leg from Side Ref Leg Depth Ref of Comb Opening F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 m...

Страница 6: ...e Cabinet Installations Cabinets are available from your dealer which allow fast convenient installation of your replace against existing walls Main Power Wall Switch Wiring To reduce the risk of re e...

Страница 7: ...ire from the wall switch to the wire grouping from the power supply and the ground stud in the junction box 9 Make sure the red wire L2 in the junction box has a closed end splice or a wire nut proper...

Страница 8: ...y 240 Volt Unit Installation 1 Locate the voltage selection switch under the logset on the left front corner of the unit 2 Check the switch position to ensure it is in the 240 Volt position 3 Loosen t...

Страница 9: ...e two pins of the support 5 Place the center log B112 on the ember lava rock Use the notches under the center portion of B112 to locate it properly 6 Place the bottom left log B113 into position by re...

Страница 10: ...f life NOTE For the sake of convenience you may wish to consider replacing all the light bulbs if one of them burns out 1 Turn OFF the power to the unit at the main service panel 2 If the replace has...

Страница 11: ...anual Reset FRONT REAR 13 13 BLACK 2 14 BLACK COIL 6 5 4 3 2 8 3 15 3 BLACK 4 BLACK 21 WHITE 18 WHITE 19 WHITE 20 WHITE 17 WHITE WHITE 2 WHITE 7 BLACK 12 BROWN 8 BLACK 14 BLACK 11 RED 5 RED 1 5 4 6 12...

Страница 12: ...BLACK 3 BLACK 4 BLACK FP1450 BREF wiring diagram w remote 6 Electrical Wiring Diagram with Integral Remote Control For Units with Ceramic Log Sets Refer to Figures 6 7 Component Identi cation 1 Heater...

Страница 13: ...9 10 17 7 3 20 WHITE 10 BLACK 3 BLACK 4 BLACK BLACK BLACK RED WHITE FP1541 BREF heat wiring 1 05 Component Identi cation 1 Heater Element 9 Light Bulb 2 Limit Control 175 20 DIF 10 Light Socket w Wir...

Страница 14: ...mbly 6 CFM Wire req d Electrical Wiring Diagram without Heater and Integral Remote Control FP1540 Fig 14 Wiring diagram for models without heat BREF30NH BREF36NH BREF42NH 5 WHITE 2 BLACK L1 N G 3 BLAC...

Страница 15: ...with integral remote control have pre programmed matched pair receiver transmitters already set with randomly selected house codes It is highly unlikely that the replace code will ever need to be rele...

Страница 16: ...ef fects of the replace This switch is normally illuminated to indicate that there is electrical power to the unit 2 Heater Control The heater control acts to turn the heater ON and OFF as well as set...

Страница 17: ...4758 BREF older parts 5 05 14 10 18 BREF42 BREF42R CFM Specialty Home Products reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any t...

Страница 18: ...rol 10002987 10002987 10002987 10002987 6 Fan w Bracket Assembly 10004695 10004695 10004695 10004695 7 Sensor 230 F Manual Reset 10004720 10004720 10004720 10004720 8 Knob Flame Speed Heater Controls...

Страница 19: ...o make changes in design materials speci cations prices and discontinue colors and products at any time without notice BREF30 36 42 BREF30NH 36NH 42NH Electric Fireplace BREF30 36 BREF30 36NH BREF42 B...

Страница 20: ...62 10004262 4 Rocker Switch Illuminated 10001393 10001393 10001393 10001393 10001393 10001393 5 Thermostat Heater Control 10002987 10002987 10002987 6 Fan w Bracket Assembly 10004695 10004695 10004695...

Страница 21: ...10004758 BREF Electric Fireplace 21...

Страница 22: ...10004758 BREF Electric Fireplace 22...

Страница 23: ...LF GARANTIE DE BASE CFM Specialty Home Products aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Majestic Fireplaces contre tous d fauts de fabrication et de mati res premi res po...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: