background image

10004758

BREF Electric Fireplace

10

8.  Place the right front log (G5) in position on the 

ember lava rock. Use the notches under the log front 
right to have a proper location.

LG324

BREF42 logs

1/04

G2

G1

G4

G3

G5

LG324

Fig. 7

  BREF42/BREF42R ceramic log placement.

To reduce the risk of fire, electrical shock 
or personal injury, disconnect all power 
coming to the fireplace at the main service 
panel before attempting any maintenance 
or cleaning.

Replacing Light Bulbs

This fireplace uses four (4) clear, 120 Volt, 60 Watt,  
E-12 socket base (small base, chandelier candle-type) 
light bulbs. These lights are located under the ember 
bed of the unit. 

Do not exceed 60 Watts per bulb. Use of 
higher-rated bulbs may result in fire, caus-
ing property damage, personal injury, or 
loss of life.

NOTE:     For the sake of convenience, you may wish 
to consider replacing all the light bulbs if one of 
them burns out.

1.  Turn OFF the power to the unit at the main service 

panel.

2.  If the fireplace has been operating, allow it to cool.
3.  Open glass (if applicable); open steel curtain.
4.  Remove the log. Remove the two (2) screws, one 

on each side of the ember bed/plate support log set 
down. Remove the ember bed/plate support log set.

5.  Examine the bulbs to determine which one(s) need 

to be replaced (if you are not going to replace all).

7.  Install new light bulb(s) by screwing in while holding 

the socket.

8.  Reinstall the ember bed, log set, glass door, and 

steel curtain.

Cleaning Trim

Clean the trim using a soft cloth you have slightly damp-
ened with lemon oil; then buff with a clean soft cloth.

NOTE:   You can obtain lemon oil at super-markets 
and hardware stores. Do not use commercially 
made brass polish or household cleaners, as these 
products will damage the trim.

Содержание BREF30, BREF36, BREF42, BREF30NH, BREF36NH, BREF42NH, BREF36R, BREF42R

Страница 1: ...NG IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY SERVICE MUST BE PERFORMED BY...

Страница 2: ...20 Volt Unit Installation 8 120 Volt NH Unit Installation 8 240 Volt Unit Installation 8 Resetting the Temperature Cutout Switch 8 Screen Kit Installation 9 Service Instructions Maintenance of Motor 9...

Страница 3: ...or sparking parts inside Do not use it in areas where gasoline paint or ammable liquids are used or stored This replace should not be used as a drying rack for clothing nor should Christmas stockings...

Страница 4: ...89 mm 41 1041mm 46 1191mm L 14 356 mm 14 356mm 16 406mm M 37 953 mm 37 953mm 49 1245mm N 54 1372 mm 54 1372mm 69 1765mm O 27 686 mm 27 686mm 35 895mm N 5 8 16mm Recessed Nailing Flange G H Rough Openi...

Страница 5: ...leg minimum installation Mantel Mantel Leg from Side Ref Leg Depth Ref of Comb Opening F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 m...

Страница 6: ...e Cabinet Installations Cabinets are available from your dealer which allow fast convenient installation of your replace against existing walls Main Power Wall Switch Wiring To reduce the risk of re e...

Страница 7: ...ire from the wall switch to the wire grouping from the power supply and the ground stud in the junction box 9 Make sure the red wire L2 in the junction box has a closed end splice or a wire nut proper...

Страница 8: ...y 240 Volt Unit Installation 1 Locate the voltage selection switch under the logset on the left front corner of the unit 2 Check the switch position to ensure it is in the 240 Volt position 3 Loosen t...

Страница 9: ...e two pins of the support 5 Place the center log B112 on the ember lava rock Use the notches under the center portion of B112 to locate it properly 6 Place the bottom left log B113 into position by re...

Страница 10: ...f life NOTE For the sake of convenience you may wish to consider replacing all the light bulbs if one of them burns out 1 Turn OFF the power to the unit at the main service panel 2 If the replace has...

Страница 11: ...anual Reset FRONT REAR 13 13 BLACK 2 14 BLACK COIL 6 5 4 3 2 8 3 15 3 BLACK 4 BLACK 21 WHITE 18 WHITE 19 WHITE 20 WHITE 17 WHITE WHITE 2 WHITE 7 BLACK 12 BROWN 8 BLACK 14 BLACK 11 RED 5 RED 1 5 4 6 12...

Страница 12: ...BLACK 3 BLACK 4 BLACK FP1450 BREF wiring diagram w remote 6 Electrical Wiring Diagram with Integral Remote Control For Units with Ceramic Log Sets Refer to Figures 6 7 Component Identi cation 1 Heater...

Страница 13: ...9 10 17 7 3 20 WHITE 10 BLACK 3 BLACK 4 BLACK BLACK BLACK RED WHITE FP1541 BREF heat wiring 1 05 Component Identi cation 1 Heater Element 9 Light Bulb 2 Limit Control 175 20 DIF 10 Light Socket w Wir...

Страница 14: ...mbly 6 CFM Wire req d Electrical Wiring Diagram without Heater and Integral Remote Control FP1540 Fig 14 Wiring diagram for models without heat BREF30NH BREF36NH BREF42NH 5 WHITE 2 BLACK L1 N G 3 BLAC...

Страница 15: ...with integral remote control have pre programmed matched pair receiver transmitters already set with randomly selected house codes It is highly unlikely that the replace code will ever need to be rele...

Страница 16: ...ef fects of the replace This switch is normally illuminated to indicate that there is electrical power to the unit 2 Heater Control The heater control acts to turn the heater ON and OFF as well as set...

Страница 17: ...4758 BREF older parts 5 05 14 10 18 BREF42 BREF42R CFM Specialty Home Products reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any t...

Страница 18: ...rol 10002987 10002987 10002987 10002987 6 Fan w Bracket Assembly 10004695 10004695 10004695 10004695 7 Sensor 230 F Manual Reset 10004720 10004720 10004720 10004720 8 Knob Flame Speed Heater Controls...

Страница 19: ...o make changes in design materials speci cations prices and discontinue colors and products at any time without notice BREF30 36 42 BREF30NH 36NH 42NH Electric Fireplace BREF30 36 BREF30 36NH BREF42 B...

Страница 20: ...62 10004262 4 Rocker Switch Illuminated 10001393 10001393 10001393 10001393 10001393 10001393 5 Thermostat Heater Control 10002987 10002987 10002987 6 Fan w Bracket Assembly 10004695 10004695 10004695...

Страница 21: ...10004758 BREF Electric Fireplace 21...

Страница 22: ...10004758 BREF Electric Fireplace 22...

Страница 23: ...LF GARANTIE DE BASE CFM Specialty Home Products aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Majestic Fireplaces contre tous d fauts de fabrication et de mati res premi res po...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: