14
Stardance Direct Vent/Natural Vent Gas Heater
20007065
Venting System Assemlby - Direct Vent
General Information
The Stardance is approved for installation only with the
vent components listed on Page 12. Follow the vent
component instructions exactly.
For U.S. installations:
The venting system must con-
form with local codes and/or the current National Fuel
Gas Code, ANSI Z223.1/NFPA 54.
For Canadian installations:
The venting system must
conform to the current CSA B149.1 installation code.
Install the Vent Adapter Pipe
(CFM Corporation Vent Components)
1. Install the Restrictor Plate.
Consult the ‘Vent Run
Specifications’ on Page 8 to determine whether the
restrictor plate is needed. If so, put the restrictor
plate in place within the inner flue collar as shown in
Figure 16.
ST210
install restrictor plate
12/4/99 djt
ST210
Fig. 16
Install the restrictor plate only if required for the vent-
ing configuraiotn. Refer to Page 8.
2. Attach Inner Starter Pipe, (found in with the log-
set), to the next section of inner pipe.
• Run a bead of sealant about 1/2” from the upper
end of the Inner starter pipe and join the two sec-
tions together.
• Drill three pilot holes into the Inner Starter and
secure the assembly with three sheet metal screws.
(Fig. 17)
3. Dry fit the Inner Pipe assembly to the stove for
the purpose of determining the center line of the
pipe on the wall.
• Side Wall Terminations:
Dry fit the outer elbow
with the vertical outer vent and confirm the centerline
alignment with the wall thimble opening.
4. Attach the Inner Vent Assembly to the stove.
• Run a bead of sealant around the bottom end of
the starter pipe and attach the assembly to the stove
using three 1/4-20 x 3/8” Phillips screws provided in
the parts bag. (Fig. 18)
ST211
attach inner pipe
to next section
12/4/99 djt
CEMENT
First Section of Vent
Pipe
3” Inner
Starter PIpe
#8 x 1/2” Sheet
Metal Screws
ST211
Fig. 17
Connect the inner starter with the next section of in-
ner vent pipe.
ST212
attach inner assy
12/4/99 djt
CEMENT
ST212
Fig. 18
Attach inner assembly to flue collar.
5. Install the Outer Adapter Pipe. Apply a 1/4” bead
of cement around the inside wall of the pipe, about
1” from the end. Insert the pipe over the stove flue
collar, keeping the vertical seam oriented to the back
of the stove. Also, be sure to align holes on the pipe
with the holes on the flue collar of the firebox. Fasten
the pipe to the holes in the flue collar with the #12 x
1/2” sheet metal screws provided. (Fig. 19)
ST213
install outer adpater
12/6/99 djt
ST213
Fig. 19
Fasten outer pipe with #12 x 1/2” sheet metal screw.