2
30005619
5. Remove the rear shroud held by two Phillips round
head machine screw in the center and four sheet metal
screws - two on each side. This allows access to the six
hex head nuts and washers holding the damper housing
assembly and the fireback retainers.
6. Remove the damper housing assembly. First remove
the damper handle with the Allen key supplied with the
unit (Fig. 5). Locate and remove the four hex head
through bolts, two per side on the outside of the inner
back, that hold the upper fireback in place (Fig. 6). The
nuts and washers are on the outside of the back. This
may require the use of two 7/16” wrenches. Gently
rotate the damper housing down right side first and
maneuver out of the firebox by sliding left to right to
clear the damper rod from the left side. Please locate
damper rod spacer and remove from the hole in the side
for reinstalling.
7. Remove the Refractory Fireback. Locate the two hex
nuts on the outside of the inner back that hold the refrac-
tory brackets in place (Fig. 7). The nuts and washers
are on the outside of the back. This may require the
use of two 7/16” wrenches. Remove the two hex nuts
with washers and pull out the hex head cap screws
holding the brackets. This may require the use of two
7/16” wrenches. Remove the brackets. Hold the top of
the refractory fireback while removing the brackets as
it will fall forward with the brackets removed.
KT1511
remove top bolts
Fig. 3
Remove top bolts in rear corners.
KT1511
KT1512
remove flat head socket screw
Fig. 4
Remove flat head socket screw.
KT1512
KT1513
remove damper handle
Fig. 5
Remove damper handle.
KT1513
KT1514
defiant damper housing
Fig. 6
Defiant damper housing with one (1) bolt removed.
KT1514
KT1515
remove fireback brackets
Fig. 7
Remove fireback brackets.
KT1515
8. Slide the fireback brick forward and out of the unit.
9. Slide the fountain assembly out.
This completes the disassembly.
WoodmansPartsPlus.com