2a. Connect the Lock (Dry)
When using an extend power supply which uses a dry contact, ensure that
“NONE” is selected on the door power selection switch.
Fail Secure
Fail Safe
2b. Connect the Lock (Wet)
In a Wet configuration, ensure that power selection
for each door is set to the correct voltage as
outlined by the locking hardware specifications.
●
Set it to “12VDC” for 12 volt locking hardware
●
Set it to “24VDC” for 24 volt locking hardware
The AC62 is rated to power
12V locks up to 1A and
24V locks up to 500mA.
Fail Safe
LOCK (+) positive goes into NC
LOCK (-) negative and ground wire goes into COM
Fail Secure
LOCK (+) positive goes into NO
LOCK (-) negative and ground wire goes into COM
Installation
Connecting a Door 2/5
When connecting the lock in the WET
configuration, ensure the negative of
the lock goes into the COM port as
shown in the diagrams below.