Table A-2
Veritas 5U84 Primary Storage Shelf / 5U84 Expansion Storage
Shelf technical specifications
(continued)
Description
Technical specification
2214W maximum continuous output power at high line voltage
You can connect up to four storage shelves to the 5340
Appliance compute node.
Maximum output power
6.67 A at 200 - 240 VAC
AC power requirements
200V - 240 VAC
Operating voltage
50/60Hz
AC Frequency range
81% @ 10% load
89% @ 20% load
93% @ 50% load
90% @ 100% load
Power conversion efficiency
Operating: 5º to 35ºC (de-rate 5ºC above 2,133m (7,000’))
(41°F TO 95°F)
Non-operating: -40°C to 70°C (-40°F TO 158°f)
Temperature Range
Operating: 20%rh to 80%rh non-condensing
Non-operating: 5%rh to 100%rh non-condensing
Relative humidity
Sound Power Operating ≤ 8.0 Bels LWAd @ 23°
Acoustic noise
-30 to 3048m ( -100 to 10000ft)
De-rate 5°C above 2134m (7000ft)
Operating altitude
-305 to 12192m ( -1000 to 40000ft)
Non-operating altitude
0.21gRMS 5-500Hz Random
Operational vibration
5g10ms ½ Sine
Operational shock
0.3g2-200-2Hz Swept Sine.
Relocation vibration
(Non-operational)
1.04 gRMS 2-200Hz Random.
Non-operational vibration
30g10ms ½ Sine (Z-axis)
20g10ms ½ Sine(X-and Y-axes)
Non-operational shock
See
“NetBackup 5340 compute node technical specifications”
on page 72.
77
Technical specifications, Environmental/Protocol standards, and Compliance standards
Veritas 5U84 Storage Shelf technical specifications