To prepare the NetBackup 5230 appliance for the installation of the hardware
1
Verify that the appliance is turned off. Refer to this section as needed.
See
on page 85.
2
Slide the NetBackup 5230 appliance forward on the rails to the full extension.
Caution:
The unit weighs up to 65 lbs (29.5 kg). Make sure that sliding it forward
does not destabilize the rack.
3
Use these steps if it is necessary to remove the appliance from the rack.
■
Label and disconnect all cables, including the power cords, from the rear
panel of the appliance.
Warning:
If the cables are reconnected to the wrong ports, data can be
corrupted or lost when the appliance is turned on.
■
Loosen the two front screws that secure the appliance in the rack and
remove the appliance from the rack cabinet.
■
Place the unit on a grounded, ESD protective surface.
4
Do the following to remove the chassis cover:
■
Put on an ESD-compliant wrist strap or take other ESD-protective measures.
■
Remove the four screws (1) from the top of the chassis cover as shown in
the figure.
■
Press the blue thumb grips (2) to release the locks and slide the cover back
0.5 inches (1.27 cm).