Table 2-5
Drawer Sideplane LED statuses
(continued)
Activity Bar
Graph
(Green)
Logical Fault
(Amber)
Cable Fault
(Amber)
Drawer Fault
(Amber)
Power
(Green)
Status
X
X
X
On
On
Drive failure has
occurred causing
loss of availability
or redundancy
X
Flashing
X
X
On
Array in impacted
state (SES)
Indicated
Off
X
On
X
Off
Cable Fault
On
*
Off
Off
Off
On
Drive Activity
X = Disregard
*
The Activity Bar Graph is a six-segment indicator that shows activity of the SAS disk drive interface to the Sideplane.
If none of the segments are lit, then there is no SAS disk drive activity occurring. Increasing disk drive activity is
measured upward, starting with the bottom segment. When full disk drive activity occurs, all six segments are lit.
Drawer Sideplane hot swap LED indicators
Drawer Sideplane hot-swap LED indicator lights are mounted on each drawer's
Sideplane printed circuit board assembly. They are visible through each Sideplane's
metal frame when the drawer is open.
45
About the Veritas 5U84 Storage Shelves
About Veritas 5350 Appliance storage shelves