Verine Fontana HE MK2 NPHL**RN2 Скачать руководство пользователя страница 25

3.5

CHECKING FOR CLEARANCE OF COMBUSTION PRODUCTS

a)

Close all doors and windows in the room.

b)

Light the fire and allow to run for approximately 5 minutes on high

position.

c)

After approximately 5 minutes hold a smoke match just inside and

below the centre of the lower front edge of the top of the fire as shown

in figure 32 below (It is recommended that a suitable smoke match

holder is used when checking for clearance of combustion products).

All smoke generated should be drawn back into the flue. If slight

spillage occurs or if in doubt, repeat the test after a further 5-10

minutes.

d)

If spillage persists, the flue is not functioning correctly and a fault exists.

If, after investigation the fault cannot be traced and rectified, the fire

must be disconnected from the gas supply and expert advice obtained.

e)

If there is an extractor fan fitted any where in the vicinity of the

appliance, the spillage test should be repeated with the fan running on

maximum and all interconnecting doors open.

f)

After ensuring that the fire is safe to use it should be left on high

position to fully warm up. During this time a slight odour may be

noticed, this is due to the “newness” of the fire and will soon disappear.

Fig. 32

Smoke match position

10mm inside and down

from top face of central

slot

25

Содержание Fontana HE MK2 NPHL**RN2

Страница 1: ...GH EFFICIENCY LOG EFFECT ROOM HEATER Installation Maintenance User Instructions Hand these instructions to the user Model No NPHL RN2 is for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Страница 2: ...ness 18 3 3 Removal re fitting the trim 19 3 4 Lighting the appliance 20 24 3 5 Checking for clearance of combustion products 25 Section 4 Maintenance 4 1 Removal of the burner controls assembly 26 4...

Страница 3: ...54 0 kg Appliance Efficiency Declaration The efficiency of this appliance has been measured as specified in BS 7977 1 2009 and the result is 71 The gross calorific value of the fuel has been used for...

Страница 4: ...58 Clay Flue Blocks and Terminals 7 IS 813 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B When Insta...

Страница 5: ...wall The appliance must however stand on a non combustible base that is a minimum thickness of 12mm 1 5 INSTALLATION TO PLASTERED WALL SURFACES If installing to a plastered wall all material must be...

Страница 6: ...all bracket IMPORTANT NOTE BEFORE PROCEEDING WITH THE INSTALLATION This product requires a minimum effective flue height of 4 0 metres of minimum circular cross sectional area 125mm If installing the...

Страница 7: ...n extra please order part number 1125 130260 from your local Verine stockist 7 Minimum 50mm at sides Minimum 50mm at rear Combustion Chamber Dimension A Opening Width 750mm Dim A Dim B Dimension B Ope...

Страница 8: ...or servicing purposes If installing without a flue liner please ensure that sufficient depth is available in the opening to collect a minimum volumetric area of 12 litres 0 012m3 of flue debris This i...

Страница 9: ...area immediately above the fire is required see figure 7 above If there is no existing openings within either triangle proceed with forming the opening However if opening or beams occur within either...

Страница 10: ...ure 8 9 below shows the hole centres in the mounting flanges of the combustion chamber Fig 8 b DO NOT SECURE THE COMBUSTION CHAMBER INTO THE OPENING AT THIS POINT AS ACCESS WILL STILL BE REQUIRED TO R...

Страница 11: ...sound Always insert the grommet into the entry point used a sharp blow with a hammer or chisel will be sufficient to knock out the opening selected in the firebox and with the grommet fitted cut with...

Страница 12: ...ncy baffle c If the product is fitted into a Class 2 flue of diameter 125mm 5 then the restrictor baffle must not be fitted It should also be noted that if fitting into a 125mm 5 diameter flue that th...

Страница 13: ...brackets as shown below in figure 15 These are clamped together to form the seal between the glass frame assembly and the combustion chamber Fig 15 NOTE Always ensure that a consistent seal between t...

Страница 14: ...the burner gauze as shown below in figure 16 onto the raised platform Fig 16 b Place the bark chippings over the burner as shown below in figure 17 do not allow the bark chippings to cover the area ar...

Страница 15: ...e log as shown below in figure 18 using the groove in the base log as a guide for placement Fig 18 d Fit Log C into position on left hand side of the fuel bed base log as shown below in figure 19 usin...

Страница 16: ...s shown below in figure 20 using the groove in Log A as a guide for placement Fig 20 e Fit log G into position at the left hand side of the fuel bed base log A as shown below in figure 21 using the gr...

Страница 17: ...o position at the centre of the fuel bed as shown below in figure 23 using the groove in the base log in the base log as a guide for position Fig 23 Warning Use only the logs supplied with the fire Wh...

Страница 18: ...a tipping site licensed for the disposal of industrial waste Protective clothing is not required when handling these arrticles but we do recommend you follow the normal hygiene rules of not smoking ea...

Страница 19: ...e onto the base of the fire If the stainless steel insert is required this is optional to fit then push it into the front panel at this stage Fig 24 b Fit the front panel and optional stainless steel...

Страница 20: ...ER mode 3 4 1 Operation of the Fire in MANUAL mode a Locate the ON OFF switch on the appliance it is situated behind the controls access cover at the bottom of the fire Ensure that the on off switch o...

Страница 21: ...w on the handset twice LO will be displayed NOTE The flame will go to HIGH rate heat input before going to designated LOW rate heat input To return back to HIGH rate heat input press the LARGE flame b...

Страница 22: ...g the day or if setting the same temperature for day and night the fire will compensate for the generally cooler evening temperatures and automatically increase the heat input level accordingly c To s...

Страница 23: ...d as per figure 30 below and the time flashes Set the hour by pressing the UP large flame and set the minutes in ten minute increments by pressing the DOWN small flame as necessary then press OFF butt...

Страница 24: ...the Remote Handset a Simultanelously press the UP large flame arrow and DOWN small flame arrow buttons on the remote handset b Press the UP large flame arrow to set the hour and the DOWN small flame a...

Страница 25: ...epeat the test after a further 5 10 minutes d If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified the fire mus...

Страница 26: ...be carried out 4 1 Removing the burner assembly from the fire 4 1 1 Isolate the gas supply 4 1 2 Remove trim from the front of the fire as shown in section 3 3 4 1 3 Remove the glass frame assembly f...

Страница 27: ...emble with a new pilot assembly and carry out a gas tightness test after re assembly 4 4 Removing the Gas Control Valve 4 4 1 Isolate the gas supply Remove the burner controls assembly as detailed in...

Страница 28: ...of the handset on the handset Parts Shortlist Glass frame assembly 1148 159240 Mertik gas control valve B 92200 Receiver unit B 153140 Thermostatic handset B 148120 Oxypilot B 128100 Complete log set...

Страница 29: ...least 300mm above the top of the appliance and the depth of the shelf does not exceed 150mm The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance abo...

Страница 30: ...nces Servicing should be carried out annually by a competent person such as a GAS SAFE registered engineer It is a condition of Verine guarantees schemes that this is carried out by a competent person...

Страница 31: ...ut If this occurs leave the fire for at least three minutes then follow the lighting procedure as described in the previous section In the event of repeated operation a GAS SAFE registered gas install...

Страница 32: ...PERATURE mode and TIMER mode 5 4 1 Operation of the Fire in MANUAL mode a Locate the ON OFF switch on the appliance it is situated behind the controls access cover at the bottom of the fire Ensure tha...

Страница 33: ...ow on the handset twice LO will be displayed NOTE The flame will go to HIGH rate heat input before going to designated LOW rate heat input To return back to HIGH rate heat input press the LARGE flame...

Страница 34: ...g the day or if setting the same temperature for day and night the fire will compensate for the generally cooler evening temperatures and automatically increase the heat input level accordingly c To s...

Страница 35: ...yed as per figure 6 below and the time flashes Set the hour by pressing the UP large flame and set the minutes in ten minute increments by pressing the DOWN small flame as necessary then press OFF but...

Страница 36: ...the Remote Handset a Simultanelously press the UP large flame arrow and DOWN small flame arrow buttons on the remote handset b Press the UP large flame arrow to set the hour and the DOWN small flame a...

Страница 37: ...materials without gloves could cause skin irritation The fuelbed should never be washed or exposed to any cleaning agents or water Any damaged parts must be replaced by contacting your dealer whose d...

Страница 38: ...er gauze as shown below in figure 8 onto the raised platform Fig 8 b Place the bark chippings over the burner as shown below in figure 9 do not allow the bark chippings to cover the area around the pi...

Страница 39: ...e log as shown below in figure 10 using the groove in the base log as a guide for placement Fig 10 d Fit Log C into position on left hand side of the fuel bed base log as shown below in figure 11 usin...

Страница 40: ...s shown below in figure 12 using the groove in Log A as a guide for placement Fig 12 e Fit log G into position at the left hand side of the fuel bed base log A as shown below in figure 13 using the gr...

Страница 41: ...ase log as shown below in figure 14 using the groove in the base log as a guide for placement Fig 14 g Fit log E into position at the centre of the fuel bed as shown below in figure 15 using the groov...

Страница 42: ...and after working on the fire When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty polythene bag clearly labelled as RCF waste This i...

Страница 43: ...tom of the combustion chamber by the two hinge clamp brackets as shown below in figure 17 These are clamped together to form the seal between the glass frame assembly and the combustion chamber Fig 17...

Страница 44: ...fit then push it into the front panel at this stage Fig 18 b Fit the front panel and optional stainless steel insert if required onto the product by hooking the retaining lugs into the slots on the co...

Страница 45: ...es stockists whose details can be found on our web site www bfm europe com in the stockist section Complete log set B 161110 Base log B 161250 Log B B 109710 Log C B 109720 Log D B 109730 Log E B 1097...

Страница 46: ...the exact accuracy of descriptions and illustrations cannot be guaranteed Part No B 161180 Issue 3 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Telephone Gene...

Отзывы: