S
YSTEM
M
ODE
- VTM
Download
52
E
355/
E
265 U
SER
AND
B
EST
P
RACTICES
G
UIDE
Where
#
in
-p#
is the comm port number of the USB device as seen in the
Device Manager on the PC.
Figure 20
Number of USB COM Port on the Device Manager/Command
for Download
15
After completion of download, press CANCEL to exit from download menu
and then select Restart to manually exit from VTM.
16
OS starts the software installation process one component at a time. The
AUTHENTICATE
message is displayed when signature and certificates are
verified otherwise
FAILED
message is displayed. Installation is incomplete
after a
FAILED
message.
If you have difficulty starting
ddl
command in PC, check if some other program in
PC already has access to this comm port. If you are using a dongle, check the
UART<->USB switch setting and ensure that USB is set.
DDL Utility
Direct Download Utility (DDL) is used to transfer files from PC to e355. This Utility
tool is available in Verix SDK.
It is recommended to add this utility tool to PATH environment variable in PC for
convenience of accessing it from any location in PC.
For more information on DDL tool usage and its arguments, refer to
Verix eVo
Volume III: Operating System Programming Tools Reference Manual, VPN -
DOC00303.
Load e355 Nova Package
Please enter port #: 9
Opened COM9, 115200 baud
...
Connected to E355 terminal
File sponsorCert.crt 956 bytes
Config *unzip=NOVA-01.A1.02.zip
File NOVA-01.A1.02.zip 3838000
NOTE
It is recommended to use USB downloads over serial as USB download is ten
times faster than serial.
Содержание e265
Страница 1: ...Verifone Part Number DOC087 080 EN A Revision A e355 e265 User and Best Practices Guide...
Страница 6: ...CONTENTS 6 E355 E265 USER AND BEST PRACTICES GUIDE...
Страница 10: ...PREFACE Conventions and Acronyms 10 E355 E265 USER AND BEST PRACTICES GUIDE...
Страница 64: ...SYSTEM MODE VTM Software Versions 64 E355 E265 USER AND BEST PRACTICES GUIDE...
Страница 70: ...LOGGING OPTIONS logdump 70 E355 E265 USER AND BEST PRACTICES GUIDE...
Страница 74: ...SOFTWARE PACKAGE Downloading 74 E355 E265 USER AND BEST PRACTICES GUIDE...
Страница 76: ...CONTROL AND BARCODE APPLICATIONS Pipe Interface 76 E355 E265 USER AND BEST PRACTICES GUIDE...