![Veridt 900W2026 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/veridt/900w2026/900w2026_installation-manual_1003913014.webp)
VERIDT INC · Middleton, WI 53562
1 4
www.veridt.com
2022
• T E C H N I C A L N O T E •
Verify Identify
Standard Wiegand
Wire Color
Signal
Black
Ground
Green
Wiegand 0
White
Wiegand 1
Orange
Tamper Switch
Brown
Access Granted
Red
+ 12V DC
Stealth Standard Serial RS-485
Wire Color
Signal
Black
Ground
Blue
RS-485 -
Yellow
RS-485 +
Orange
Tamper Switch
Red
+ 12V DC
OSDP Wiring of Tamper Switch
For OSDP applications, connect the Tamper Switch signal, orange wire Pin 9, to the INPUT 1 signal, Gray wire
on pin 8.
DO NOT connect the Tamper switch signal to a control panel. The state of this switch is reported as a
response to an osdp_LSTAT command