VC4000DAQ Manual
45
0-30 mph
0-60 mph
0-80 mph
0-100 ft
0-300 ft
0-5 sec
Custom
AutoStart 1/4 mile
4. Choose one of the presets shown or choose Custom. For
Custom, scroll down to
Speed
and press
ENTER / YES
.
5. Type in the “START FROM” speed in mph or kph and press
ENTER / YES
. Then type in the “UP TO” speed and press
ENTER / YES
.
6. The VC4000 will display 'Auto-Start-Ready' and the current
G reading.
7. Accelerate the vehicle until the VC4000 beeps indicating it
has reached the preset speed.
Information available after an acceleration test (using User Type
General)
After an acceleration run, bring the vehicle to a complete stop. The
ending Time, Speed, Distance, instantaneous Gx and Average Gx
will be displayed.
Press the up or down arrow keys to scroll through any data points
reached (waypoints) during the test.
QuickSet Accel Run
1/4 mile 8.90 sec
170.0 mph Gx= 0.38
Avg Gx= 0.88
Accel Display (4)
Engineering Use
VC4000DAQ Manual
46
Data from the Vericom VC4000 QuickData™
Distance Time Speed RPM G-Force
1/4
Mile
1000
ft
1/8
Mile
330
ft
60
ft
30
ft
15
ft
60
mph
30
mph
Peak Gx=
Peak Gy=
Peak HP=
Press the Graph/Data key to display graphs of the run. Press
Speed, Distance, G-Force, RPM or Sensor. Press the same key
again to scroll through multiple graphs, such as pressing the G-Force
key to scroll through longitudinal, lateral or vertical G-Force.
The Acceleration Mode operating limits are:
Imperial Metric
Maximum time
99.9 seconds
99.9 seconds
Maximum speed
255 MPH
511 KPH
Maximum distance
9000 feet
1800 meters
Maximum acceleration
+2G
+2G
The VC4000 can
continuously
display and store any internal or
external sensor. You may choose to not save the data to conserve
memory space if you only require on-screen viewing.
Monitor Data