Dura 65
14 | Page
Version 1.0v-05/2021
© Verder International B.V
Dura 65 - Hose and Flange Assembly
5.8.1
Port Flange Assembly without Insert
5.8.2
Port Flange Assembly with Insert
For Dura 65, install the hose in position and
protruding 40 mm from the pump housing
flange face (the side through which the hose
had been inserted).
40 mm
Figure 10 Hose and Flange Assembly (just for information)
5.8 Flange Assembly
5.8.1 Port Flange Assembly Without
Insert
Ensure the hose is installed as indicated in Figure 10
Hose and Flange Assembly.
1. Insert the clamp ring over the hose with the large
diameter towards the pump and ensure that the
hose is protruding 5 to 10 mm past the clamp
ring.
2. Fit the O-Ring to the port flange.
3. Apply some lubricant compatible with the pumped
media to the port flange.
4. Make sure the O-Ring is in place in the face
groove and push the port flange into the hose to
-
gether.
5. Install the 4 bolts.
6. Tighten the bolts in a 1–3–4–2 sequence until the
flange is evenly fitted. All 4 bolts should be fitted
to each flange to avoid compromising the perfor
-
mance of the pump.
7. Ensure that the hose can be seen only through
the drain port on the port flange.
(Figure 10c)
8. Run the pump forward and stop when the hose is
protruding 40 mm from the pump housing flange
face. (Figure 10a)
9. Repeat steps 1 - 6 to complete assembly.
10.
Fit the ¼ turn flange connector to both ports.
5.8.2 Port Flange Assembly With
Insert
1.
Fit the ¼ turn flange connector to both ports.
2. Slide
the insert into the port flange and fix it with
a counter flange.
(Figure 10b)
3. Fit the flange-insert unit to the suction port.
(Fig-
ure 10d)
4. Make sure the flange-insert unit is in the right
position, then remove the counter flange. (Figure
10f)
5. Repeat steps 1 - 9 from (
g
5.8.1 Port Flange
Assembly Without Insert) to complete assembly.
For Dura 65 port flange assembly with insert,
we advise to use a counter flange to fix the
insert and push the flange-insert unit in.
Figure 9 Clamp Ring Inserted
Clamp Ring
Pump Housing
Flange Face
Figure 10a
Figure 10b
CAUTION
Figure 10c
Figure 10d
Figure 10e
Figure 10f
the hose is protruding
5 to 10 mm past the
clamp ring
drain port