Dura 5 - 35
4.0v-06.2013
14 | Page
5.5
Electrical connection
DANGER
Risk to health due to electric shock!
All electrical work must be carried out by qualified
electricians.
DANGER
Death or crushing of limbs caused by falling loads!
Use lifting gear appropriate for the total weight to be
transported.
Do not stand under suspended loads
5.5.1
Connecting to power supply
1.
Connect motor to the rated power supply. Ensure the
correct gland is used and that the earth connection is
made and secured.
2.
Run the pump slowly to ensure correct rotation.
Figure 20 Electrical connection
5.6
Installing the Hose
5.6.1
Inserting the hose
Possible when the motor has been wired up or
alternately it can be done by removing the fan cover
and rotating the shaft.
Figure 21 Inserting Hose
1.
Add some lubricant to the pump housing.
2.
Lubricate the hose generously with Verderlube /
Verdersil.
3.
Insert the hose into the lower port.
4.
Run the pump forward until the hose is fed through the
pump casing and is protruding from the port flange
mounting face by about 30 mm.
–
This can be done either by connecting the pump to a
motor that can be run slowly or by manually rotating
the shaft after removing the fan cover.
5.6.2
Fitting the port flange (Standard assembly)
Hose in position and protruding about 30mm on the
inlet side
(the side through which the hose had been
inserted)
1.
Apply some lubricant compatible with the pumped
media to the port flange.
2.
Push the port flange-insert into the hose.
Figure 22 aligning the port flange
3.
Install the 4 bolts.
4.
Tighten the bolts in a 1–3–4–2 sequence until the
flange is evenly fitted, but not completely tightened,
leaving about 10mm slack.
Figure 23 Fitting the port flange