Performance Charts
Test Conditions: The pump was tested in water with
the inlet submerged. The air pressure was set at 7
bar (100 psi).
How to Use the Charts
1. Choose a flow rate and outlet pressure that falls
below the Power Limit Curve. Conditions outside
of the curve will decrease the life of the pump.
2. Set the VFD frequency corresponding to the
desired flow rate. Flow rates will increase with
outlet pressure lower than 0.7 bar (10 psi) and
with high inlet head pressure.
High speed gear ratio pumps with option Ax5K5
Pump Speed Cycles per Minute
Outlet
Pressure
bar, MPa
(PSI)
0
0
53
80
106
133
160
186
212
238
27
0.7, 0.07
(10)
1.4, 0.14
(20)
2.1, 0.21
(30)
2.8, 0.28
(40)
3.4, 0.34
(50)
4.1, 0.41
(60)
4.8, 0.48
(70)
5.5, 0.55
(80)
6.2, 0.62
(90)
6.9, 0.69
(100)
76
(20)
151
(40)
227
(60)
303
(80)
379
(100)
454
(120)
530
(140)
Fluid Flow —lpm (gpm)
24
859.0761
Содержание VERDERAIR VA-E50
Страница 27: ...Dimensions Dimensions Aluminum or cast iron pump with compressor 859 0761 27 ...
Страница 28: ...Dimensions Aluminum or cast iron pump without compressor 28 859 0761 ...
Страница 31: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump with compressor 859 0761 31 ...
Страница 32: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump without compressor 32 859 0761 ...
Страница 34: ...Dimensions Stainless steel pump with compressor 34 859 0761 ...
Страница 35: ...Dimensions Stainless steel pump without compressor 859 0761 35 ...
Страница 37: ...Notes Notes 859 0761 37 ...